Installing i-on Control Units
Page 33
Step 6: Connect the battery
Note:
Connecting the battery does not start the system.
Fit a 7Ah lead-acid battery in the bottom-right corner of the control unit and secure with a
strap provided.
Connect the battery leads to the battery (red to positive and black to negative), and
connect the other end to the PCB (Figure 9). Also connect the transformer lead to the PCB
(Figure 9).
Step 7: Connect the mains cable
WARNING:
ENSURE THAT THE MAINS SUPPLY IS DISCONNECTED AND ISOLATED.
Connect the mains cable to the terminal block (Figure13) and fit a strain-relief tie. Confirm
the mains cable is routed as shown in Figure 11.
Do not apply power until after the lid is re-fitted.
Figure 13. i-on30R+ and i-on40H+: Mains connections
Step 8: Re-fit the lid, switch on and configure the system
WARNING:
During initial power-up, keypad sounders and any internal loudspeaker may
give an alarm tone. If you are working at the top of a ladder, make sure that the sudden
noise does not startle you and cause a fall.
Re-fit the lid, then switch on the mains supply to the control unit.
Go through the initial configuration prompts and set up the system as described in the
Configuration Guide
. You are prompted to specify installer and user codes during initial
system configuration.
It is recommended that you connect the control unit to the internet and enable "Level 4
Update" in the installer and user menus. When you enter your installer code, the system
can then check online whether later versions of the firmware or language file exist, and
prompt you to install them. Please refer to the
Configuration Guide
for further details.