Scantronic 9449 User Manual Download Page 3

Enter 

Go To Control 

Building 

Panel 

?

?

Zone 

Tamper 

Panic 

Reset any panic buttons 

activated, then 

?

?

?

?

Zone 

Service 

"beep" 

"beep" 

"beep" 

"beep" 

?

EE

EE

EE

EE

Z1

Z1

Z1

Z1

Z2

Z2

Z2

Z2

Z3

Z3

Z3

Z3

Z4

Z4

Z4

Z4

Z5

Z5

Z5

Z5

Z6

Z6

Z6

Z6

Z7

Z7

Z7

Z7

Tamper 

Tamper 

Tamper 

Tamper 

6

0

Reset Code 

AFTER AN ALARM

Fire Alarm: The system gives a fire alarm by
sounding a warbling tone from the internal sounder.
1. Evacuate the premises and call the Fire Brigade.
Do not attempt to unset the alarm.
2. When the premises are safe, follow the instruc­
tions below.
To switch the bells off:  Key-in your user code.
The sounders will stop and the zone light(s) for the
detectors that triggered the alarm will glow.
Tamper or Panic Alarm: If you hear the internal
sounder when the system  is off then look at the
control panel:
If the Tamper light glows then key-in your user code
to stop the sounder. Call your alarm installer for
service.
If the tamper light is off see if a PA zone light is
glowing. Deal with the cause of the alarm first. Next,
reset the panic button, then switch the alarm system
bells off and reset the system (see below).
Reset system: You must reset the system before it
can be used again. If the Service LED is OFF then
you can reset the system yourself. Key-in your
access code again. All the zone lights should go off.
The system is now ready for use.
If the Service LED is ON, you must call for an
engineer to reset the system.
Remote Reset: If your alarm is connected to a
central station then the system may use remote
reset (ask your Installer). With this method the
keypad displays a special four digit code. Report
this code to the central station, who then give you
another code to let you to reset the system. Have a
pencil and paper ready to note down the code.
1. Key in your user code to silence the bells.
The display shows the zone and Service LEDs ON.
2. Key in your user code again.
The display shows a four digit code by lighting the
zone lamps one at a time. The small numbers to the
right of the lamps give the digits. The keypad
sounder gives a short tone each time the digit
changes. (If there is no light glowing then the digit is
“zero”.)
3. Note down the code. If necessary, press Enter to
make the keypad repeat the code.
4. Report the code to the central station.

496281 Issue 1 

Summary of Contents for 9449

Page 1: ... Scantronic Leading the way in security ...

Page 2: ...ing the sounder gives an interrupted tone and a zone light glows then a detector is being triggered maybe a door or window is open Key in your user code to stop the tone Check the indicated zone s and if possible correct the cause of the alarm Try setting the system again If the fault persists call your alarm installer Note that it may be normal for certain zone lights to glow as you walk past det...

Page 3: ...rst Next reset the panic button then switch the alarm system bells off and reset the system see below Reset system You must reset the system before it can be used again If the Service LED is OFF then you can reset the system yourself Key in your access code again All the zone lights should go off The system is now ready for use If the Service LED is ON you must call for an engineer to reset the sy...

Page 4: ...ck to 0000 Duress Code Your system provides a Duress Code When the system is new the code is inactive and set to To activate the code change it to a number you can remember using the same method as changing the access codes Do not use 9999 or the same number as your other access codes To inactivate the duress code change it back to If your system is connected to a central station then it will send...

Page 5: ...he internal sounder chimes when the chime zones operate Note that the Installer must program your chime zones TELEPHONE LINE FAILURE If you see the Fault and Service LEDs flashing and a short tone every few seconds then the system has detected a fault on the telephone line connecting the system to the central station Key in your user code to stop the tone The Fault and Service LEDs will continue t...

Page 6: ...sure the system is unset Key in 9 plus ENTER followed by your user code The keypad displays the digits of the date and time one by one on the zone and tamper LEDs The keypad sounder beeps each time the system shows a new digit The EE zone LED represents 1 and the Tamper LED represents 9 If all LEDs are off when the keypad beeps then the digit 0 zero When the keypad has completed showing the date a...

Page 7: ...E Power Z1 Z2 Fault Z3 Z4 Service Z5 Z6 Z7 Tamper Alarm zone 1 Call engineer EE Z1 Z2 Z3 Z4 Service Z5 Z6 Z7 Tamper Power Fault Mains fail EE Power Z1 Z2 Fault Z3 Z4 Service Z5 Z6 Z7 Tamper A tamper has activated but is now clear Call engineer EE Power Z1 Z2 Fault Z3 Z4 Service Z5 Z6 Z7 Tamper 24Hr Technical or PA zone active Reset PA switch if necessary EE Z1 Z2 Z3 Z4 Z5 Z6 Z7 Tamper beep Power F...

Page 8: ...ffort has been made to ensure that the contents of this book are correct errors and omissions excepted However neither the authors nor Scantronic accept any liability for loss or damage caused or alleged to be caused directly or indirectly by this book The contents of this book are subject to change without notice Printed and published in the U K 7 496281 Issue 1 ...