4. Programming
user walks down the stairs to unset the system the hall PIR will start the
entry timer, to remind them that the system is set.
After setting up Areas and Levels:
Use Menu 45 to set the alarm response for each Level.
Use Menu 46 to set the re-arm response for each Level.
Use Menu 47 to allocate keypad exit and entry tones to Levels.
Use Menu 51 to assign outputs types. The Bell output can be pro-
grammed to be normally energised (Negative removed) or normally
de-energised (Negative applied). The factory default is normally
energised.
Use Menu 53 to set Bell Delay and Run Times if necessary.
Use Menu 65 to select the Reset type (customer, Installer, Anticode or
RedCare).
See the 808 User Guide for instructions on how to set up user information.
Figure 21 shows in table form how the system should be configured for the
example. Figure 22 shows the programming steps needed. Note that some
Menus will appear during programming but are not used for the example.