background image

4603

Programmable Multi-

Function Transmitter

INST

ALLA

TION AND PROGRAMMING GUIDE

4603 english new style  23/10/1998 13:27  Page 1

Summary of Contents for 4603

Page 1: ...4603 Programmable Multi Function Transmitter I N S T A L L A T I O N A N D P R O G R A M M I N G G U I D E 4603 english new style 23 10 1998 13 27 Page 1 ...

Page 2: ...e that the contents of this book are correct However neither the authors nor Scantronic accept any liability for loss or damage caused or alleged to be caused directly or indirectly by this book The contents of this book are subject to change without notice Printed and published in the U K 4603 english new style 23 10 1998 13 27 Page 2 ...

Page 3: ...ut terminals each with a positive ve Ground Gnd and an input connection A B C for convenience Two groups of DIL switches are provided one group of 12 controls the site unit code settings and the smaller group of 6 control the operating modes The aerial connection takes a 6BA or similar nut bolt enabling the small spring helical aerial supplied to be fitted directly to the PCB or if required a flyi...

Page 4: ...l transmitter with built in delay timer 4 Alarm tamper with restore on both alarm and tamper 5 2 channel bi directional trigger on both A and B inputs 6 Two channel bi directional trigger only on B input 7 Two channel with B input configured for tilt switch includes built in delay timer and pre transmit warning bleep 8 Four channel mode Four button capability but will send only the first button pr...

Page 5: ... 10 site code bits together with data bit B active and data bit A as per input A i e input A linked to ground will give data bit A inactive Any activity on input A is otherwise ignored whilst the unit is disarmed If the key switch is opened the panel goes into a fixed 25 second exit period during which the bleeper sounds At the end of this period the bleeper goes quiet and input A becomes armed If...

Page 6: ...ntact remains open for a further 14 seconds a transmission is triggered with data bit B active logic 1 The mercury switch closing at any time before the transmission resets the timer to zero and silences the bleeper If a B type transmission has been sent closing the mercury switch contacts triggers another transmission with both A B data bits set inactive logic 0 This is effectively a restore tran...

Page 7: ... options for the speed at which the inputs are scanned which also has a direct affect on battery life If the FAST switch is off the inputs are scanned every 100mS This is suitable for most types of input except very fast push buttons and gives battery life of typically 7 years If the FAST switch is ON the inputs are scanned every 20mS with a reduced battery life of typically 4 years If the speed m...

Page 8: ...aerial Input Connections Inputs A B C D will accept 25 metres of multi core security type cable and can tolerate series resistances of up to 500 ohms Frequency 173 225 MHz Details of other country frequencies are available on request Approval DTI approved to specifications MPT1328 44 approval no RTD 3984 Size 90mm x 63mm Operating and storage temperatures 0 deg C to 50 deg C Programmable Multi Fun...

Page 9: ...608 10 Note Link 1 must be on 0 and link 2 on 2 2k7Resistor VE I PA GND VE I PB GND VE I P CON GND TAMPER KEYSWITCH Note N O to Set 4603 50 60 in mode 3 Note It is not possible to wire the PIR Tamper Switch through the pins provided as it will not work to the 4603 50 60 Transmitter correctly 4603 english new style 23 10 1998 13 28 Page 7 ...

Page 10: ...594 544136 Scantronic Nieuwe Haven 11 3311 AP Dordrecht NEDERLAND Tel 31 0 78 6134888 Fax 31 0 78 6134343 Scantronic 5 Avenue del Vill Antony 94410 Saint Maurice FRANCE Tel 33 0 1 49 76 00 71 Fax 33 0 1 49 76 00 58 Scantronic C Marques de San Juan 7 y 9 46015 VALENCIA ESPANA Tel 34 9 6 349 88 00 Fax 34 9 6 349 51 27 Scantronic by Si Tronic Via S Allende 12 14 20091 Bresso MI ITALIA TEL 39 0 2 66 5...

Reviews: