Settings by Type
General Tuning
P25 Trunking
Motorola Trunking
Stalker/Sweeper Settings
Weather Settings
Digital Tuning
EDACS Trunking
Zeromatic Settings
Misc Settings
General Tuning
SQ Wait 1
The amount of time to wait for a signal on a frequency while scanning (scan speed) in the
same
. The lower the value the faster the scan
speed, the higher the value, the slower the scan speed. There is probably a possibility of setting the value too low and the scanner would not stop on
active frequencies. These values also impact searching and tuning ('Tune' search). [
]
Default Value: 10
(10 ms).
Values:
Enter
1-200
(1 - 200 ms).
Suggested
value
5-7
.
Menu Help Text:
Squelch wait time, same band
Win500 Name
- Extended Settings>General Tuning>
In-band
Timeout
PSREdit Name
- Weather/Advanced Configuration>Expert Settings>
Squelch Time Same Band
SQ Wait 2
The amount of time to wait for a signal on a frequency while scanning (scan speed) in a
different
The lower the value the faster the scan
speed, the higher the value, the slower the scan speed. There is probably a possibility of setting the value too low and the scanner would not stop on
active frequencies. These values also impact searching and tuning. [
Default Value: 15
(15 ms).
Values:
Enter
1-200
(1 - 200 ms).
Suggested
value
10-12
.
Menu Help Text:
Squelch wait time, new band
Win500 Name
- Extended Settings>General Tuning>
Timeout
PSREdit Name
- Weather/Advanced Configuration>Expert Settings>
Squelch Time Different Band
RF SQ Fade
Length of time to wait before closing the squelch after lost signal (squelch tail).
Default Value: 10
(100 ms).
Values:
Enter
0-99
(0 - 990 ms).
Menu Help Text:
RF SQ fade delay
Win500 Name
- Extended Settings>General Tuning>
Fade Timeout
PSREdit Name
- Weather/Advanced Configuration>Expert Settings>
Fade Time
SearchTunes
Maximum number of frequencies to check in each limit, service, or stalker/sweeper search
object
while scanning.
Default Value: 0
(entire range).
Values:
Enter
0-9999
tunes (frequencies).
Menu Help Text:
Max search tunes per scan loop 0=entire range
Win500 Name
- Extended Settings>General Tuning>
SRCH tunes in SCAN
PSREdit Name
- Weather/Advanced Configuration>Sweeper/Search
Options>
Max Search Tunes per Scan Cycle
Digital Tuning
DG Int Prime
Controls how long the scanner waits to automatically detect digital (P25
) transmissions, when the type of transmission isn't
known/expected ahead of time. [
]
Default Value: 60
(600 ms).
Values:
Enter
1-100
(10 - 1000 ms).
Suggested value
30
.
Menu Help Text:
Preselect
audio
Win500 Name
- Extended Settings>Digital>
Digital detect timeout
PSREdit Name
- Weather/Advanced Configuration>Expert Settings>
Digital Detect Time
Noise Thresh
Sounds like the number of noisy 'bits' that the scanner will allow prior to retuning or adjusting with the
. External noise appearing at the
front end of a receiver, plus the noise added by the receiver itself; determines a noise threshold that has to be exceeded by the minimum discernible
signal. [
Default Value: 20
.
Values:
Enter
1-128
.
Suggested value
45-50
.
Menu Help Text:
Noise threshold value for DSP
Win500 Name
- Extended Settings>Digital>
Noise threshold
PSREdit Name
- Weather/Advanced Configuration>Expert Settings>
Noise Threshold
P25 Trunking
96CC HD2 TO
Length of time to wait for P25 control channel detection timeout.
Default Value: 30
(300 ms).
Values:
Enter
10-250
(100 - 2500 ms).
Menu Help Text:
9600CC SQ to HD2 timeout
Win500 Name
- Extended Settings>P25 Trunking>
detect timeout
PSREdit Name
- Weather/Advanced Configuration>P25 Settings>
Timeout
96VC SQ TO
Length of time to wait for P25 voice channel
squelch timeout. Go lower to release squelch sooner, go up to extend squelch longer. [
]
Default Value: 50
(500 ms).
Values:
Enter
10-250
(100 - 2500 ms).
Menu Help Text:
9600VC RF SQ timeout
Win500 Name
- Extended Settings>P25 Trunking>
timeout
PSREdit Name
- Weather/Advanced Configuration>P25 Settings>
Timeout
96VC XF TO
Length of time to wait for P25 voice channel digital
Default Value: 100
(1000 ms).
Values:
Enter
10-250
(100 - 2500 ms).
Menu Help Text:
9600VC
to XF timeout
Win500 Name
- Extended Settings>P25 Trunking>
Digital timeout
PSREdit Name
- Weather/Advanced Configuration>P25 Settings>
Timeout
HD2 Qual DG
Length of time to check for a P25 control channel before unmuting in '
Analyze
'.
Default Value: 100
(1000 ms).
Values:
Enter
10-250
(100 - 2500 ms).
Menu Help Text:
qual time to unmute 96CC
Win500 Name
- Extended Settings>P25 Trunking>
Qualify
in analyze
PSREdit Name
- Weather/Advanced Configuration>HD2 Settings>
Qualify Time (Digital)
CTCSS/DCS/NAC
ACSQ SrcInt
Length of time to wait for a CTCSS/DCS/
auto squelch search
.
Default Value 500
(500 ms).
Values:
Enter
10-2000
(10 - 2000 ms).
Menu Help Text:
Wait for
srch
Win500 Name
- Extended Settings>CTCSS/DCS/NAC>
Search Interval
PSREdit Name
- Weather/Advanced Configuration>HD5 Settings>
Search Delay