RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
447
innovators for industry
Comments
•
Note that
half
the period length must be specified for
HalfPeriod
).
•
If
HalfPeriod
= 0 and/or
PulseLength1
= 0, no laser signals will be outputted.
• If the softstart mode is used (see
),
HalfPeriod
should not be smaller than 104
(this is not automatically checked). This value corresponds to a laser pulse frequency of
approx. 308 kHz.
• If
PulseLength1
is larger than the output period (2 ·
HalfPeriod
), the laser will be
permanently on.
• The time base setting applies only for the parameters of this command.
• For RTC
®
4 compatibility mode, SCANLAB generally recommends setting the time base
to 8 MHz. In this mode, a time base of 1 MHz should only be chosen if necessary.
• Refer to
chapter 7.4 "Laser Control", page 128
, for details.
• In RTC
®
5 mode, the command
set_laser_timing
.
• The signal level is defined via
• In laser mode 4 and laser mode 6, the time base for signals LASER1 and LASER2 is inde-
pendent of
TimeBase
and always 1/64
µ
s (in RTC
®
5 mode) or 1/8
µ
s (in RTC
®
4 compat-
ibility mode).
RTC
®
4
RTC
®
5
• With the RTC
®
5, the pulse lengths of laser signals LASER1 and LASER2 are always iden-
tical.
• Clock frequency:
- in RTC
®
5 mode: fixed clock frequency of 64 MHz
- for the RTC
®
4 and in RTC
®
4 compatibility mode: 1 MHz or 8 MHz
References
Undelayed
Short
List Command
set_list_jump
Function
Execution produces an unconditional jump to the specified address within the list buffer.
The next command there will be executed immediately without delay.
Call
set_list_jump( Pos )
Parameter
Pos
absolute jump address [0 … (2
20
–1)] as an unsigned 32-bit value
Comments
• The
set_list_jump
command is synonymous with
– see the comments
there.
RTC
®
4
RTC
®
5 unchanged functionality (except for the extended range of values)
References
Delayed Short
List Command
set_laser_timing