RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
431
innovators for industry
Normal
List Command
set_fly_y
Function
activates Processing-on-the-fly correction for compensation of a linear workpiece-
movement in the Y direction (based on position values transferred to the RTC
®
5 via
encoder counter Encoder1) and sets the corresponding scaling factor. Encoder counter
Encoder1 may be reset (see comments).
Restriction
If the Processing-on-the-fly option is not enabled, then the command terminates the
Processing-on-the-fly process (even though it couldn’t have been activated).
Call
set_fly_y( ScaleY )
Parameter
Scale
scaling factor for the Y direction (encoder counter Encoder1) in
bits/count
(as a 64-bit IEEE floating point value);
allowed range: 1/256
|
ScaleY
|
16000.0
Comments
• For Processing-on-the-fly correction and determination of the scaling factor, see
"Processing-on-the-fly (Optional)", page 177
.
• If unallowed parameter values are supplied (e.g. for
ScaleY
= 0), then
set_fly_y
will not
activate a Processing-on-the-fly correction or will deactivate a Processing-on-the-fly
correction previously activated via
set_fly_y
(but will not deactivate any other
Processing-on-the-fly correction). The latter case leads to a jump (at jump speed) to the
endpoint of the most recently executed vector or arc command (without “
set_fly_y
“
Processing-on-the-fly correction).
• The various Processing-on-the-fly corrections can’t be arbitrarily combined (see the
• For deactivating Processing-on-the-fly correction, see
, bit#9 can be set in advance to specify whether encoder counter
Encoder1 should reset immediately via
set_fly_y
or only after the subsequent external
start trigger (i.e. via the subsequent external start signal or
command, possibly postponed by a track delay set via
; also see
, bit#2).
• You can also switch on
/
set_fly_y
Processing-on-the-fly correction via the
command.
RTC
®
4
RTC
®
5 unchanged functionality (except for the extended range of values)
In RTC
®
4 compatibility mode, the RTC
®
5 multiplies the specified scaling factor by 16 (the
permissible range of values is correspondingly reduced).
Version info
Last change with version OUT 515
References
,
,