6.0 RS232 Computer Local Control Function
:(
CONSOLE
)
6.1 Connect the RS232 CONSOLE port to the COM port of the host by an F/M RS232 straight
cable (pin 2 to pin 2; pin 3 to pin 3, pin 5 to pin 5).
The Matrix communication format is 9600, 8, N, 1 (9600 bps, 8 data bits, no parity check, 1 stop bit)
6.2 Operation Instruction format:
C Space + par Enter
The Matrix will reply OK once string is correct, NG in case of incorrect string
TX[x] SP [y]
is the string to switch on output x the input y
PWR SP [z]
is the string to put the matrix in Standby and On status
[SYMBOL]
[PARAMETER]
--------------- ------------------------------------------------------
x
1 | 2 | 3 | 4
Output 1 to 4
y
01 | 02 | 03 | 04 | 00
Input 1 to 4, 00: Off
z
00 | 01
00: Standby, 01: On
Example:
-To route input 4 to output 1, send the following string:
Command Input
TX1
SP
04
Enter
-To route input 2 to output 3, send the following string:
Command Input
TX3
SP
02
Enter
-To put in standby the matrix, send the following string:
Command
PWR SP
00
Enter
Command are case insensitive. Be sure that your terminal after Enter (0D Hex) character