4
Bottom Switch & Button:
HKM01T-4K
Switch
/Button
Function
↓
↑
1
Group
0
1
2
RS232
Normal
Reserve
3
Normal
Reserve
4
EDID
Management
4 5
↓
↓
= Select default 1080p LPCM 2CH EDID
↑
↓
= Select RX monitor EDID
↓
↑
= Select TX loop out monitor EDID
↑
↑
= Reserve
5
6
Reserve Function
Normal
Reserve
Button
Copy EDID
Based on Switch 4 & 5 setting to do EDID copy
HKM01R-4K
Switch
/Button
Function
↓
↑
1
Group
0
1
2
RS232
Normal
Reserve
Button 1
Function Switch
MAC, IP, Baud rate, Updated EDID(Reserve)
Button 2
Baud rate setting
115200, 57600, 38400, 19200, 14400, 9600, 4800, 2400, 1200
Rotary Switch:
HKM01-4K built in rotary switch for pairing devices and the rotary switch can be used to
switch 0-F channel pairing with group setting of switch 1. The channel number and group
setting of the transmitter and receiver must be same to be connected each other, total up to
32 (16 for each group) pairs could be setup at one switch.
Audio
:
Transmitter
Analog audio
Input
Line In
Transmitter
Analog audio
Output
Line Out
Receiver
Microphone
Input
Mic In
Receiver
Analog audio
output
Line Out
Description
○
○
○
○
Transmitter analog audio to receiver
analog audio
Receiver microphone to Transmitter
analog audio
(Monitor Mute)
○
X
X
X
Transmitter analog input to Monitor
output
X
X
X
○
HDMI audio to Receiver analog audio
(support LPCM 2CH, monitor mute)
X
X
X
X
HDMI audio to Monitor audio output
○ = connect audio connector , X = disconnect audio connector
※ When the receiver's analog output (LINE OUT) connector or microphone input (MIC IN) connector have
been connected, the monitor sound will be turned off. (Mute).