NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1010\91010042.idw
91010042
opstilling med knærør
25-08-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
M3 NR.:
MATERIALE:
DATO:
SIGN:
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 1010\91010046.idw
91010046
ovn med 90 gr røgrør
21-09-2016
hms
Scan 1010
VÆGT:
AREAL:
N/A
N/A
DIM.:
Scan A/S
11
LOAD-BEARING FOUNDATION
All items in our product range come under the category of lightweight fireplaces and stoves and do not normally require any rein-
forcement of the beam structure. They can be positioned on ordinary beams/floor.
You should of course make sure that the foundation on which the stove is positioned can indeed support the weight of the stove
and, where applicable, a steel chimney, if you have opted for this solution. In case of doubt about the carrying capacity of the
floor, please consult a building expert.
FLOOR PLATE
If you are placing the stove on a flammable floor, you must comply with the national and local regulations on the size of any
non-flammable subsurface required to cover the floor around the stove.
Your local Scan dealer can advise you on regulations concerning protection of flammable materials in the vicinity of your stove.
The floor plate’s function is to protect the floor and flammable material against any sparks that may occur.
EXISTING CHIMNEY AND PRE-FABRICATED ELEMENT CHIMNEY
If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chim-
ney sweep, for advice. These experts will also let you know if your chimney needs renovating.
¬
When connecting a pre-fabricated element chimney, follow the manufacturer’s connection instructions for the relevant
chimney type
CONNECTION BETWEEN STOVE AND STEEL CHIMNEY
Your Scan dealer, or local chimney sweep, can advise you on choosing a make and type of steel chimney. This ensures that the
chimney will match your wood-burning stove.
REQUIREMENTS FOR CHIMNEY
The chimney must have a diameter of min. 148 mm and be labelled T400 and G for soot testing. The length must be min. 4,5
metres.
If you opt to connect the stove with an elbow pipe, you should use a curved elbow, as this gives a better draught.
If you connect the stove with a sharp elbow pipe, the cleansing lid must be placed in the vertical part so that the
horizontal part can be cleaned through here.
The requirements to the chimney and the flue pipe in terms of safety distances must be met.
¬
Choosing the wrong length or diameter of chimney could impair functionality
¬
Always comply exactly with the instructions provided by the chimney supplier
Curved elbow pipe
Sharp elbow pipe