Summary of Contents for Andersen 4-5

Page 1: ...tion and Operating Instructions 3 Andersen 4 5 Manual Version P00 The manuals which are enclosed with the product must be kept throughout the product s entire service life Scan Andersen 4 5 BP Convect...

Page 2: ...2...

Page 3: ...ification and documentation for the product 2 0 Technical data Material Cast iron Finish Black paint Fuel Wood Log length max 30 cm Flue outlet Top rear Flue pipe dimension Ext 125 mm 130 mm Weight wi...

Page 4: ...S Soap stone model Scan Andersen 4 5 Convection model 474 164 457 758 651 400 457 651 821 164 400 Y 850 X Min measurments floor plate X Y according to national laws and regulations Center rear smoke...

Page 5: ...m distance to combustible wall Scan Andersen 4 5 S Scan Andersen 4 5 S Inclusive rear optional convection shield part no 50013025 900209 P00 150 314 150 407 314 150 407 150 300 464 300 300 532 537 300...

Page 6: ...shielded fuel pipe all the way down to the product 900209 P00 Combustible wall Firewall 724 214 50 850 1252 214 50 50 891 712 100 332 287 214 50 850 1252 214 50 899 50 796 782 295 100 368 Minimum dist...

Page 7: ...menting the Clean Air Act 1993 including designation and supervision of smoke control areas and you can contact them for details of Clean Air Act requirements 3 1 Fire Prevention Measures There is a c...

Page 8: ...s it to be swept Be aware of the fact that it is particularly important that connections have a certain flexibility in order to prevent movement in the installation leading to cracks Chimney draught S...

Page 9: ...e soap stone panels fig 4G using the nuts and screws provided fig 4E and fig 4F 1 Attach the loose smoke outlet fig 5 and place the soap stone top 4 7 Smoke outlet The product has been prepared for a...

Page 10: ...nockout fig 9B Fig 10 A 1 Remove the cast iron cover fig 10A from inside the burn chamber 2 Fit the cast iron cover in the top outlet hole using the same parts Fig 11 C A B 1 Place the provided gasket...

Page 11: ...Handle If you want a firm handle you can mount the screw M5x20mm that you will find in the service bag The vertical position of the handle can be adjusted by turning the set screw on the locking devi...

Page 12: ...can Andersen 4 5 S J tul F 145 S From manual Scan Andersen 4 5 J tul F 145 1 Cut off the lower part of the Scan Andersen 4 5 label 2 Put the Scan Andersen label on top of the J tul 145 label 5 0 Daily...

Page 13: ...eated may cause extreme stress in the chimney Add fuel to the fire in moderation Avoid smouldering fires as this produces the most pollution The fire is best when it is burning well and the smoke from...

Page 14: ...A 1 Lift the exhaust deflector fig 18A up carefully 2 Remove the pins fig 18B 3 Ease the exhaust deflector out 6 2 Replacing the burn plates inner bottom Fig 19 B A 1 Take out the baffle exhaust defle...

Page 15: ...f the fireplace We recommend that you carefully inspect your fireplace yourself after it has been swept cleaned Check all visible surfaces for cracks Also check that all joints are sealed and that the...

Page 16: ...gistering the product on jotul com and print out the extended guarantee card within three months of purchase We recommend that the guarantee card be kept together with the receipt J tul AS also guaran...

Page 17: ...ays from the date on which the fault or defect first became apparent See list of importers and dealers on our web site www jotul com If J tul is unable to meet the obligations outlined in the above gu...

Page 18: ...18...

Page 19: ...19...

Page 20: ...J tul AS P o box 1411 N 1602 Fredrikstad Norway www jotul com Cat no 10050866 P00 J tul AS Apr 2016...