14
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 68\10068900 - Manual.iam
90068010
Portal sokkel mont.
18-03-2015
sr
Scan 68
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 68\90068028.idw
90068028
Friskluft pedestal
17-04-2015
hms
Scan 68
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 68\90068029.idw
90068029
Friskluft fra gulv
20-04-2015
hms
Scan 68
VÆGT:
AREAL:
N/A
N/A
FRESH AIR INTAKE
In a well-insulated house the air used for the combustion process has to be replaced. This particularly applies to houses with
mechanical ventilation. There are different ways of making sure that air is exchanged. The most important thing is to ensure that
there is a supply of air to the room where the wood stove is located. The external wall vent must be located as close to the wood
stove as possible, and you must be able to close it when you are not using the stove.
National and local building regulations must be followed with regard to connection of a fresh air intake.
NOTE: WHEN CONNECTING THE SCAN 68 LOW BASE WITH A FRESH AIR INLET, WE RECOMMEND THAT YOU USE A SHORT,
ANGLED CONNECTION PIECE BECAUSE OF THE LIMITED SPACE IN THE BASE. (FOR EXAMPLE JØTUL PRODUCT NO.
158962
-F373).
CLOSED COMBUSTION SYSTEM
You should use the closed combustion system for the wood-burning stove if you live in a newly-built, airtight home. External
combustion air is connected through a ventilation pipe via the wall or floor.
We recommend mounting a valve in the ventilation pipe in order to avoid condensate in the stove and the pipe system, which can
be closed when the oven is not in use. It can also be an advantage to insulate the ventilation pipe.
Minimum Ø100 mm ventilation pipe, maximum length: 6 meters with a maximum of one bend.
If you want external combustion air via a wall, remove the cover plate at the rear of the stove with a pair of cutting pliers. See the
procedure in this manual.
If the external combustion air is connected at the rear, the dismounted plate must be mounted on the hole for external air in the
bottom of the stove.
NOTE: IF THE STOVE HAS A FRESH AIR CONNECTION OR CLOSED COMBUSTION, THE VENTILATION PIPE MUST BE OPEN, WHEN THE
STOVE IS IN USE.
External air supply
through the wall.
External air supply
through
the floor.
The external air supply can be connected through the pedestal or the portal by mounting the delivered connecting piece.
PORTAL
If you want to connect an
external air supply from the
bottom of the base, remove
the blind flange and mount it
at the top of the base. Then
mount the delivered connect-
ing piece under the base as
shown below.
PEDESTAL