Fresh air intake
In a well-insulated house, the air used up by the burning process has
to be replaced. This particularly applies to houses with mechanical
ventilation. There are different ways of making sure that an air
exchange takes place. The most important thing is to ensure that
there is a supply of air to the room where the wood stove is located.
The external wall vent must be located as close to the wood stove
as possible, and you must be able to close it when you are not using
the wood stove.
There are two kinds of air supply:
Air that enters the room from outside (fresh-air connection piece).
Air that is led directly into the stove's combustion chamber (external
combustion air).
National and local building regulations must be followed with
regard to the connection of fresh-air intake.
Preparing the stove for rear outlet
To connect the flue pipe, remove the cover plate as follows:
Use the tools provided (see service package) to remove the
cover plate at the rear of the wood-burning stove.
Tilt the cover plate back and forth a couple of times to release
and remove.
1.
2.
4.
Loosen the internal cover
from the inside and remo-
ve.
You
will
need
this
plate
later as a seal and a cover
for the top outlet.
5. Attach the loose collar
from the outside and use
the enclosed fittings and
the seal from the service
package to fix in place.
6.
Insert the cover plate into the hole in the top plate.
If you have selected the Scan
50-5
or
50-5
Maxi, the stove cannot be
installed using the rear outlet.
External combustion air
If you choose a Scan
50
or Scan
50
Maxi with external combustion
air, a Ø100 mm ventilation pipe is used for the installation.
The ventilation pipe is not permitted to be closable using a valve.
Ø100 mm ventilation pipe, max. length: 6 m with max. 1
bend.
•
3.
Use pliers to cut the anchor points on the heat shield baffle and
remove the shield.
Anchor points
Fitting the fresh-air connection piece
The Scan
50
and Scan
50
Maxi can be connected using a fresh-air
connection piece. Installation of the fresh-air connection piece is
shown below.