Flue collar top outlet
Your wood-burning stove has been prepared for a top outlet by the
manufacturer. Remote the cover plate from the top plate, and fit
the flue collar, the enclosed seal, and the fittings from the service
package. At the same time, fix the safety fitting crosswise to prevent
damage to the smoke deflector plate when sweeping the chimney.
Connection between stove and steel chimney
Your Scan dealer, or local chimney sweep, can advise you on
choosing a make and type of steel chimney. This ensures that the
chimney will match your wood stove. As a general rule, the length
of the flue should not be less than 3,5 m measured from the top of
the wood-burning stove.
Choosing the wrong length or diameter of steel chimney could
impair functionality.
Always observe the chimney vendor‘s instructions precisely.
Fresh air supply
In a well-insulated house, the air used up by the burning process
has to be replaced. This particularly applies to houses with mecha-
nical ventilation. There are different ways of making sure that an air
exchange takes place. The most important thing is to ensure that
there is a supply of air to the room where the wood-burning stove is
located. The external wall vent must be located as close to the wood
stove as possible, and you must be able to close it when you are not
using the wood-burning stove.
Connection piece with damper
Cover plate
Flue collar
Connection piece with damper for fresh air
If you ordered a connection piece with damper for fresh air, please
mount it as shown below.
3. Loosen the internal cover
(boiler plate) from the inside
and remove. You will need
this plate later as a seal and
a cover for the flue outlet.
4. Attach the loose collar
from the outside and use the
enclosed fittings and the seal
from the service package to
fix in place.
5. Insert the cover plate into the hole in the top plate.
Safety fitting
4
A S S E M B LY
Requirements for chimney
The chimney must be labelled T400 and G for soot testing.
Connection with 90° elbow pipe
You can also connect your wood-burning stove using a 90° elbow
pipe at the top outlet.
The cleansing lid on the elbow pipe must be located in the vertical
section of the pipe to allow cleaning of the horizontal section through
the access cover.