both the Physical and Hardware Capacity values. The precision, or number of decimal places, of the
displayed Capacity Weight value will match that previously configured for the respective channel within
the
8.5.1
Procedure
The procedure for navigating the Capacity Weight submenu follows the control flow diagram depicted
in Figure 21.
Figure 21: CAPACITY WEIGHT Control Flow Diagram
a.
Access to this menu requires that both the Dead Weight and Calibration Weight procedures be
completed. The user is prompted via a display message (Not shown in Control-Flow diagram) to
first enter any missing required parameters.
b.
For a dual-channel system, first select the desired channel for which to conduct the procedure. The
number of any chosen active channel will be indicated in the upper-left corner of the display for the
remainder of this submenu.
c.
Select and enter the desired units for Capacity Weight. Only pounds (lb) or kilograms (kg) are valid.
d.
Enter the gross Capacity Weight in the previously-selected units. The displayed default value will
match the Calibration Weight entered when the analog gain value was set to maximum given it
theoretically could be used to calibrate at all gain levels. The supported range for Capacity Weight
is from 1 up to a computed, theoretical Hardware Capacity Weight, less 1.
e.
Following entry of a Capacity Weight, the system will evaluate the data to determine the optimal
analog gain level from which to operate. This will represent the highest gain level that would not
cause saturation of the ADC output value for the entered Capacity Weight.
8.6
System Config
Select this menu option by pressing the Enter Key while the display appears as shown in Figure 22.
EXIT
Path taken when ENTER Key pressed.
Path taken when ARROW Key pressed.
Changes Value in
Selected Unit
1: CAPACITY Wt
Unit? Kilogram
1: CAPACITY Wt
Unit? Pound
1: CAPACITY Wt
50 lb