See wrap
maximum
chart
COPPER PIPE INSTRUCTIONS
1.) Follow the same instructions in
steps 1-6
for PVC, CPVC and PEX pipe.
Use Chart B for Copper
2.) Instead of a single coil wrapping around the pipe, a second one is added for copper pipe.
3.) YOU MUST KEEP THE SECOND WRAPPING IN THE SAME DIRECTION AS THE FIRST! Wrap
right over the top of the first layer continuing in the same wrapping direction as the first layer –
clockwise or counterclockwise. This second layer must also be tight and touching the prior wrap.
(Figure C)
4.) Wrap a third cable tie around the pipe and both wires.
Pull the cable tie tight. (
Figure D)
5.) Follow same instructions in
steps 7-8
for PVC, CPVC and PEX pipe.
ACTIVATING THE SYSTEM
1.) Once the power unit has been installed and the pipe has been wrapped, insert the connector end of the
AC power adaptor into the power unit. (See
Illustration A
on page 5)
2.) Plug in the transformer end of the cord into a 110-volt electrical outlet.
3.) Operation of the
ScaleBlaster
SB-75 system can be confirmed by observing the illumination of the
LED indicator located on the face of the power unit. Power on - green light on far right side will stay
lit
(Figure E)
. When pipe is wrapped and unit is turned on the far right light will stay lit and the other
lights will oscillate back and forth
(Figure F)
.
MAINTENANCE
The best feature of the
ScaleBlaster
SB-75 is that there is NO MAINTENANCE REQUIRED. No salt,
batteries, moving parts or costly repairs. Just check the LED light for proper operation.
Figure C
Figure D
SB-75
* inside dimensions
Wrap Requirement
COPPER pipe*
Pipe Size*
1/2”
3/4”
1”
1 1/4”
Layers / Wraps
/ 50 wraps
Double** / 50 wraps
Double** / 45 wraps
Double** / 40 wraps
Double**
Chart B
7
Figure E
Figure F
Power
Indicator
Signal
Indicators
(** Example - Double/50 wraps is a
total of 100 wraps. 50 wraps on first
layer and 50 on second layer.)
Never under wrap or over wrap the coil.