background image

NU2-IPC20_50-E-0918 

SCAIME SAS - Technosite Altéa - 294, rue Georges Charpak - 74100 JUVIGNY 

Tél. : +33 (0)4 50 87 78 64 - www.scaime.com 

IPC20 – IPC50 

2/2 

Us

er

 M

anua

Summary of Contents for IPC20

Page 1: ...NU2 IPC20_50 E 0918 SCAIME SAS Technosite Alt a 294 rue Georges Charpak 74100 JUVIGNY T l 33 0 4 50 87 78 64 www scaime com IPC20 IPC50 2 2 User Manual...

Page 2: ......

Page 3: ...LABLE TARE FUNCTIONS 9 REMOTE CONTROL 10 THE DISPLAY 11 IDENTIFICATION OF THE METROLOGICAL SOFTWARE 12 BASIC FUNCTIONS 13 ON 14 OFF 14 ZERO 14 AUTOMATIC TARE 15 TARE DELETION 15 PRESETTABLE TARE PT 16...

Page 4: ...DISPLAY hold 42 EXCHANGE BETWEEN NET WEIGHT AND GROSS WEIGHT net Gro 43 CONFIGURATION MENU 44 CloCk DATE AND TIME 45 preC 10 HIGH RESOLUTION READING DIVISION 45 alibi ALIBI MEMORY READING 46 setpnt RE...

Page 5: ...could expose the user to the risk of electrical shock and will render all warranty conditions null All problems with the unit or the system must be communicated to the manufacturer or the dealer from...

Page 6: ...l printer 7 Customisable printouts 8 Automatic reset when scale is switched on 8 Keyboard lock 8 Saving battery power 9 Automatic switching off 9 Available tare functions 9 Remote control 10 The displ...

Page 7: ...s an internal rechargeable battery it is charged automatically The printer is usually in STAND BY and is only powered by the weight indicator when it is time to print in order to ensure the battery ho...

Page 8: ...ion Keyboard lock requires advanced configuration Customising printouts requires advanced configuration Heading Progressive weighing number for accumulation modes Progressive ticket number Weight data...

Page 9: ...saving functions designed to increase operating time The instrument allows you to choose from specific tare functions for your needs Locked tare standard factory configuration Unlocked tare automatic...

Page 10: ...ote control The remote control requires advanced configuration Additional radio frequency remote control configurations REMOTE CONTROL The instrument can be equipped with an infrared or radio frequenc...

Page 11: ...n the display 4 The weight displayed is net There is a saved tare 5 6 The weight displayed is gross 7 Battery level 8 Metrics are being displayed 9 A locked tare is active 10 A manual tare is active 1...

Page 12: ...C off xx YY 2 sec 2 sec Prefix instrument model Version legal software Weighing program version 1 Turn off the scale 2 Follow the procedure IDENTIFICATION OF THE METROLOGICAL SOFTWARE Main features o...

Page 13: ...13 On 14 Off 14 Zero 14 Automatic tare 15 Tare deletion 15 Presettable tare PT 16 Print 17 Metrics 17 Regulation of the display brightness 18 BASIC FUNCTIONS of the scale NU2 IPC20_50 E 0918...

Page 14: ...14 ZERO 0 000 off 0 000 a a a b b b c c c 0 000 0 001 C C 2 sec ON OFF ZERO Basic functions of the scale NU2 IPC20_50 E 0918...

Page 15: ...15 kg kg a b 0 500 c 0 000 TARE a b 0 500 c 10 000 TARE a b 10 000 1 200 AUTOMATIC TARE TARE DELETION Basic functions of the scale NU2 IPC20_50 E 0918...

Page 16: ...f 000 500 PRINT 0 500 1 200 TARE b i 0 9 PRESETTABLE TARE PT Setting the tare value How to set the value or If the pallet truck has a number keypad it is possible to enter the tare quickly a Enter th...

Page 17: ...b c 10 000 C 4 sec INFo 600 000 40 000 2 000 10 000 F a PRINT b print PRINTOUT AND REPRINT OF THE LAST TICKET METRICS To reprint the last ticket for models with numerical keyboard Basic functions of t...

Page 18: ...18 2 sec c brGt 0 brGt 5 a b 10 000 ZERO REGULATION OF THE DISPLAY BRIGHTNESS Set the brightness How to set the value Basic functions of the scale NU2 IPC20_50 E 0918...

Page 19: ...19 Setting a tare value already known PT 20 30 tares archive 20 Automatic tare deletion 21 Numerical IDs 22 Date and time 23 for models with numerical keyboard ADDITIONAL FUNCTIONS NU2 IPC20_50 E 0918...

Page 20: ...NOWN PT 30 TARES ARCHIVE a Enter the tare value This memorises the most commonly used tares up to 30 to simplify retrieval with quick selection Select the memory Enter the tare value Example How to se...

Page 21: ...DELETION Automatic deletion disabled Automatic deletion en abled the tare will be deleted automatically when the pallet truck is completely unloaded Select the memory How to set the value or How to r...

Page 22: ...nabled the entered ID will be deleted automatically when the pallet truck is completely unloaded The numerical IDs zero automatically when turning off the scale Enter the required ID up to 10 digits o...

Page 23: ...23 0 000 Fun 8 a b c day month year hour Minute F 8 i DATE AND TIME Only if the option date and hour is present Additional function for models with numerical keyboard NU2 IPC20_50 E 0918...

Page 24: ...Accumulation total 28 Mixing several components formul 30 Piece counting Count 32 Weight check CheCk 35 Unit of measurement conversion Conver 38 Percentage weighing perC 39 Holding weight on the disp...

Page 25: ...ected the function the scale goes back to weighing mode Horizontal accumulation sum of the weight of several objects to obtain the total weight Vertical formulation or accumulation mixing several comp...

Page 26: ...i d g kg 2 sec 0 9 How to check calibration if necessary Check finished calibration How to adjust calibration if necessary Set the sample weight WEIGHING WITH HIGH RESOLUTION DISPLAY hi res How to set...

Page 27: ...g g WEIGHING WITH HIGH RESOLUTION DISPLAY hi res How to select the desired reading division This operating mode requires configuring an appropriate filter hi res0 hi res7 see page 25 the maximum numb...

Page 28: ...28 0 500 t 1 a b c PRINT 1 800 t 2 d e f PRINT 0 900 t 3 g h i PRINT kg kg kg How to sum the weighs HORIZONTAL ACCUMULATOR total Advanced functions of the scale NU2 IPC20_50 E 0918...

Page 29: ...weight Number of weighs Number of weighs Total weight Total weight Advanced functions of the scale With numerical keyboard F 7 simply shows the current total without any printout reset With numerical...

Page 30: ...250 0 030 0 000 t 1 d a e b f c PRINT 0 100 t 2 g h i PRINT 0 100 t 3 j k l PRINT TARE kg kg kg kg How to sum the weighs MIXING SEVERAL COMPONENTS formul Advanced functions of the scale NU2 IPC20_50 E...

Page 31: ...of weighs Total weight Total weight Advanced functions of the scale How to reset the total With numerical keyboard F 7 simply shows the current total without any printout reset With numerical keyboar...

Page 32: ...elected reference quantity For a correct sampling the reference quantity must have a weight of at least 0 1 of the maximum scale capacity With the numerical keyboard the combination of the F 5 keys al...

Page 33: ...are value see page 15 or tare the empty container and fill it with the pieces to count How to switch between pieces count and weight Enter the average unit weight How to set the value oppure 0 9 With...

Page 34: ...ces How to set the value With the numerical keyboard the combination of the F 5 keys allows to type the desired quantity in any amount Sampling in progress please wait With the numerical keyboard the...

Page 35: ...xample 1 To check a weight of 1000 g with 5 g tolerance that is between 995 g and 1005 g set t01000 l00005 h00005 Example 2 To check a weight of 500 g with 10 g 20 g tolerance that is between 480 g an...

Page 36: ...T kg kg kg Enter the lower tolerance How to start the check with automatic target acquisition How to check the weight How to set the value How to set the value or or Enter the higher tolerance 0 0 9 9...

Page 37: ...00000 h00000 a b d 2 sec MODE kg kg How to update the nominal weight with known reference weight How to update the nominal weight with automatic target acquisition How to edit the check thresholds Adv...

Page 38: ...unces oz 1g 0 03527 Stones st 1g 0 00016 Karats kt 1g 5 00000 Grains gr 1g 15 43240 How to convert the unit of measurement into pounds standard mode Converting the unit of measurement with free conver...

Page 39: ...keyboard the combination of the F 7 keys allows to modify the sam pling time The more the time the more the sampling precision Percentage check I How to acuire the 100 reference II How to check the w...

Page 40: ...TARE 2 sec MODE kg kg kg 0 9 Example of formula Product RP28K 1 2127A3 50 2 23AB4 30 3 Water 20 Dose 500g Enter the total quantity to achieve How to set the value or Percentage metering Advanced funct...

Page 41: ...41 0 0 j k l 30 0 20 0 m p n o 0 0 C 100 0 MODE 0 500 TARE kg You can go from weight in to wei ght in kg at any time Advanced functions of the scale PERCENTAGE WEIGHT PERC NU2 IPC20_50 E 0918...

Page 42: ...MODE 200 000 200 000 kg kg kg kg kg kg How to deactivate the function The weight on the display is held even when the scale is unloaded HOLDING WEIGHT ON THE DISPLAY hold How to activate the function...

Page 43: ...00 a b 0 500 c 0 000 TARE a b 0 000 1 200 kg kg kg kg kg kg You can go from net weight to gross weight at any time EXCHANGE BETWEEN NET WEIGHT AND GROSS WEIGHT net Gro Advanced functions of the scale...

Page 44: ...gh resolution reading division preC 10 45 Alibi memory reading alibi 46 Relay output setpnt 46 Weighing filters filter 47 Display backlighting sCreen 48 Tare tare 49 Automatic switching off autoff 49...

Page 45: ...sCreen autoff tik res preC 10 Clock A B C D E F G H I J K L 00 00 00 00 00 no yes i C MENU Visible only if the date time option is available This functions allows you to display the weight with ten t...

Page 46: ...ssed as follows 00000 000000 for example 00001 000021 The first value is the re write number the second value is the weighing identifi cation number Enter the re write number Reading channel Saved wei...

Page 47: ...r filtering incidence Increasing the incidence give the weight more stability We recommend weighing several times changing the incidence until you ob tain the best compromise between reactivity and st...

Page 48: ...i C alibi setpnt filter tare on prin reset diaG sCreen autoff tik res Clock preC 10 MENU Backlighting Always on On when weight is un stable Brightness Backlighting colour Display lock for use by the...

Page 49: ...g on switching on printer radio module or other device powered via Vaux The tare is saved Manual deletion Tare automatically deleted when scale is unloaded Tare functions inhibited Tare automatically...

Page 50: ...J K L i C alibi setpnt filter tare on prin reset diaG sCreen autoff tik res Clock preC 10 MENU Reserved for technical staff 1 5 Sec How to enter How to browse Page 44 tik res TICKET NUMBER RESET rese...

Page 51: ...51 FAQ Frequently Asked Questions Print 51 Accumulation 51 Tare 51 Weighing 52 Piece counter 52 NU2 IPC20_50 E 0918...

Page 52: ...The weight is unstable unStAb The net or gross weight is negative loW Underload o overload ______ o un oVEr The scale was not unloaded after the last printing no 0 unS The weight is insufficient for...

Page 53: ...le weighing filter has been selected The weight is unstable Check the active weighing filter see page 47 If the support surface is subjected to vibrations from machinery or moving vehicles move the sc...

Page 54: ...printing Add weight and try again under Underload Load the scale to restore a valid weight condition If the problem persists contact customer service over Overload Unload the scale to restore a valid...

Page 55: ...individual in charge of the scale operation must ensure that all safety regulations in force in the country of use are applied ensuring that the appliance is used in accordance with the purpose it is...

Page 56: ...56 NOTES NU2 IPC20_50 E 0918...

Page 57: ...57 NOTES NU2 IPC20_50 E 0918...

Page 58: ...58 NOTES NU2 IPC20_50 E 0918...

Page 59: ......

Page 60: ...ight to bring any modification without prior notice All rights reserved Headquarter Technosite Alt a 294 Rue Georges Charpak 74100 JUVIGNY FRANCE SCAIME SAS 294 RUE GEORGES CHARPAK CS 50501 74105 ANNE...

Reviews: