31
SC Aster Total – Error Messages & Protections
The white LED light will blink 10 times when the power button is held for longer than 15
seconds, and the battery of the Aster Total will automatically shut down the output�
When the resistance is less than 0�15 ohm, a short circuit occurs� In this case, the LED will flash
3 times�
If the device detects that no atomizer head is installed, the white LED flashes slowly when the
fire button is pressed�
When the voltage of the device is below 3�3V, the white LED will flash 40 times and the device
will automatically shut down the output� Please charge the device to reactivate it�
15 Seconds Protection
Short Circuit Protection
No Atomizer Protection
Low Voltage Protection