DIGITAL HYDROMETER

SBS-2003

INSTRUCTION

MANUAL

SBS-2003

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

Summary of Contents for SBS-2003

Page 1: ...DIGITAL HYDROMETER p_p J Menu Temp S G Count DIGITAL HYDROMETER SBS 2003 INSTRUCTION MANUAL SBS 2003 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431...

Page 2: ...e eyes flush with cold clean water for a minimum of 15 minutes and seek immediate medical attention Thank you for purchasing the SBS 2003 Digital Hydrometer Please read and follow the below instructio...

Page 3: ...e is needed during measurement when the temperature of the electrolyte varies greatly from the ambient temperature The SBS 2003 compensates for the temperature of the sample automatically by detecting...

Page 4: ...ng Battery 8 Zero setting 10 Measuring Sample 12 Temperature 14 Settings Menu 15 Bluetooth Data Logging 17 Alternate Method of Bluetooth Data Transfer 26 Error Messages 29 Maintenance 31 Troubleshooti...

Page 5: ...ld it down for 2 seconds to turn off the instrument In the menu pressing the START performs that menu item 5 Battery cover Open the lid to insert remove the battery 6 Tube pump Squeeze the pump to cre...

Page 6: ...with the prism and are measured 9 Sample tube Sample is drawn through the sample tube 10 Sample tube cap Used to protect the tip of the sample tube N R Q P O DIGITAL HYDROMETER p_p J Menu Temp S G Co...

Page 7: ...tube into the hole located at the bottom of the sample chamber until it stops Figure 3 2 Fit the sample tube into the groove on the side by pushing it in with the thumb Figure 4 3 Inserting Sample Tub...

Page 8: ...strap to prevent dropping the instrument as shown on the front cover of this manual 2 Loop the strap through the strap adjuster buckle Figure 6 1 Put the strap through the rectangular opening at the b...

Page 9: ...th the OPEN position marker Figure 7 Warning Do not touch the battery with wet fingers to avoid shock Caution Insert the battery with the correct polarity plus and minus terminals Operating with a bat...

Page 10: ...03 is on Remove the battery from the instrument before putting it into long term storage Any generic 9V battery can be used Always zero set the instrument after the battery is replaced When the voltag...

Page 11: ...ample tube in water Squeeze and then release the tube pump Water is drawn up into the sample chamber Figure 10 6 Zero setting Figure 10 Figure 9 DIGITAL HYDROMETER Menu Temp S G Count DIGITAL HYDROMET...

Page 12: ...til th battery runs out or is removed Allow the instrument to acclimatize to the ambien temperature before taking measurements Zero setting can be performed anytime Use distilled or de ionized water f...

Page 13: ...n This process will help prevent erroneous readings resulting from cross contamination with the previous sample measured Figure 14 Caution To avoid accidental exposure to harmful chemicals always wear...

Page 14: ...ngs To clean the prism surface use a soft tissue soaked with ethyl or isopropyl alcohol If electrolyte is left in the sample chamber for a long period of time corrosion of the prism occurs and will ca...

Page 15: ...point to Temp Figure 17 To switch between Celsius and Fahrenheit see settings menu see page 16 8 Temperature Figure 17 Note The temperature indicated is the temperature of the sample chamber not nece...

Page 16: ...press the START button to connect the unit to the PC A dash will appear on the right side and start to shift to the left side and data transfer begins The counter value is displayed in the meantime O...

Page 17: ...hrenheit and press the START key to confirm your selection Press the SELECT key to cancel 5 End Exit the Bluetooth menu Press the START key while End is displayed The screen will return to the count v...

Page 18: ...after each download from the SBS 2003 you will have the option of Printing Saving or Cut and Paste into another worksheet from the Template 10 1 1 Copy the SBS 2003 Template from the CD onto the deskt...

Page 19: ...er the SBS 2003 Menu System When in the Menu System press the SELECT button one time to reach the Snd command and press the START button to activate the Bluetooth data transmission Will scroll across...

Page 20: ...et or by cutting and pasting the readings from the Template into another Excel Worksheet or Workbook If multiple strings of readings are downloaded at the same time cut and paste each string of data i...

Page 21: ...al com port will be assigned Launch Tera Term A new connection window will appear Select the COM Click Setup and open Terminal Figure 21 Select the COM from the com port options and configure other se...

Page 22: ...being transferred will appear from 1 through the last count 66 in the Figure 24 and then Snd will appear Simultaneously the transferred data will appear on the Tera Term window Figure 25 The specifica...

Page 23: ...between the equipment and the receiver Connect the equipment to outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for...

Page 24: ...y be present LLL Out of range error Figure 26 2 The sample measured lower than the specified measuremen range HHH Out of range error Figure 26 3 The sample measured higher than the specified measureme...

Page 25: ...n error Figure 26 8 The Err message will appear when the unit cannot find a Bluetooth enabled device while searching or connect to the paired device during data transfer after attempting to do so for...

Page 26: ...rganic solvents such as paint thinners petroleum ether or gasoline on the plastic body Draw and discharge distilled or de ionized water several times to rinse the prism after use Make sure that no liq...

Page 27: ...ure 27 and check if the prism and sample chamber are dirty or wet Wipe them clean with a soft tissue Figure 28 Check the leakage at sample tube and sample chamber NOTE Check periodically for any leaka...

Page 28: ...act between the contact pins and battery by using a screwdriver to return the pins to the normal position The sample chamber sample chamber hook and or tube pump may have been freed from the normal po...

Page 29: ...ement Is the O ring damaged in the sample chamber Is the tube pump damaged Is the sample tube damaged Is the cover of the sample chamber damaged Is the prism surface stained or blurred Is the sample t...

Page 30: ...the O ring for deformation o damage Figure 31 If the O ring has been deformed or damaged replace it with a new O ring available through your supplier After replacing the O ring properly replace the s...

Page 31: ...d or air can be observed if the tube pump sample tube or cover has been damaged or i the sample tube is loose If damage is found replace the damaged part Two spare sample tubes are included Replacemen...

Page 32: ...04 to 122 F Temperature 1 C 10 to 30 C 1 8 F 50 to 86 F Resolution Specific gravity 0 001 Temperature 0 1 C 0 1 F Temperature compensation range 5 0 to 40 0 C 41 0 to 104 0 F Measurement time Approxim...

Page 33: ...38...

Page 34: ...ge Battery Systems LLC Instruction Manual for SBS 2003 Digital Hydrometer Rev 04 15 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot...