SBC Q.PS-PEL-240x Manual Download Page 8

Saia-Burgess Controls AG

Manual Q.PS-PEL-240x 24 VDC Power Supply Unit │ Document 27-646; Version ENG01 │ 2015-08-27

1-8

Safety measures 

Installation

1

Installation
Safety measures before installation.

This equipment is to be protected against improper use. Components are not to be bent or 

isolation spacing changed, especially through handling and transport.

The contact with electrical components and terminals is to be avoided. Always disconnect 

the equipment from the mains supply, before commencing installation or wiring. The product 

description, technical information in this data sheet and the marking on the equipment ratings 

plate are to be observed.

Installation

Installation must be carried out according to the prevailing local conditions and safety regula

-

tions (e.g. VDE 0100) national accident prevention regulations (e.g. UVV-VBG4 or BGV A3) 

and the generally accepted rules of technology. This equipment is a component designed for 

installation into electrical systems and machines, and fulfils the requirements of the low volta

-

ge guidelines (2014/35/EU).
The required minimum spacing to neighboring components must be observed to guaran

-

tee the required cooling. When installed into machinery, the normal operation is forbidden 

until it is determined that the machine fulfils the requirements of the machinery guidelines 

(2014/30/EU). EN 60204 must be observed. The EMC requirements (2004/108/EG) must be 

fulfilled before operation is commenced. The observance of the required limitations for the 

EMC legislation is the responsibility of the manufacturer of the installation or machinery.

Disposal

WEEE Direc tive:

At the end of their useful life the packaging and

product should be disposed of by a suitable

recycling centre.

Do not dispose of with normal household waste.

Do not burn.

Summary of Contents for Q.PS-PEL-240x

Page 1: ...Document 27 646 Version ENG01 2015 08 27 Manual Q PS PEL 240x 24 VDC Power Supply Unit ...

Page 2: ...s Document version Version Changes Published Remarks ENG01 2015 08 27 2015 08 27 New document Brands and trademarks Saia PCD and Saia PG5 are registered trademarks of Saia Burgess Controls AG Technical modifications are based on the current state of the art technology Saia Burgess Controls AG 2015 All rights reserved Published in Switzerland ...

Page 3: ...unting packages all units feature overvoltage and short circuit protection Features Stabilised and adjustable output voltage Power output OK LED Parallel connection capability Spring loaded connector system DIN rail mounting Specifications Input Input rated voltage 100 to 240 Vac Input voltage range 85 to 264 Vac Input frequency range 44 to 66 Hz Inrush current limiter 30 A NTC Recommended 6A 10A ...

Page 4: ...onductors Use Cu only rated 60 C or 60 75 C Installation Install in Pollution Degree 2 environment Feedback voltage max 30 Vdc Safety standards Safety EN61558 2 17 EN60950 SELV EMC EN61204 UL cURus cULus GL GL Germanischer Lloyd Indication Output power OK Green LED DC OK Input output terminals Connection technology Push in Conductor cross section single wire 0 2 2 5 mm2 Conductor cross section str...

Page 5: ...C 2 8 A 55 C Efficiency 82 typ 88 typ Current rating at any mounting position Max 0 9 A Max 2 4 A Weight 0 17 kg 0 3 kg Dimensions 54 89 54 mm 90 89 54 mm Voltage Current Characteristic for short circuit and overload The output of the device is electrically protected against overload and short circuit Uout V Output Charac Iout A teristic U I Chara teristic c 1 1 IN N I Current overload protection ...

Page 6: ...Manual Q PS PEL 240x 24 VDC Power Supply Unit Document 27 646 Version ENG01 2015 08 27 1 6 1 Dimensions Datasheet Dimensions H D1 D2 W Model Q PS PEL 2401 Q PS PEL 2403 W 54 mm 90 mm H 89 mm 89 mm D1 54 mm 54 mm D2 59 mm 59 mm ...

Page 7: ...he adjustment screw anticlockwise reduces the voltage output VADJ Mount Dismount Mount unit by placing the DIN rail guide on the upper edge of the DIN rail and snapping it into place with a downward motion Dismount unit by levering the lower catch open with a screwdriver pulling the lower edge forward and unhooking from the top of the DIN rail Parallel connection If units have their outputs connec...

Page 8: ...l accident prevention regulations e g UVV VBG4 or BGV A3 and the generally accepted rules of technology This equipment is a component designed for installation into electrical systems and machines and fulfils the requirements of the low volta ge guidelines 2014 35 EU The required minimum spacing to neighboring components must be observed to guaran tee the required cooling When installed into machi...

Page 9: ...3280 Murten Switzerland Phone 41 26 580 30 00 Fax 41 26 580 34 99 Email support support saia pcd com Supportsite www sbc support com SBC site www saia pcd com International Represetatives www saia pcd com contact SBC Sales Companies Postal address for returns from customers of the Swiss Sales office Saia Burgess Controls AG Service Après Vente Bahnhofstrasse 18 3280 Murten Switzerland ...