For the data output to the USB port, you can adjust the length, position, etc. from the option below, and 
the final data will appear in the last line. 
Select the output code position: adjust the length and position of the output part of the EPC number 
Choose the output format: there are decimal, hexadecimal and standard Wiegand, there are more output 
formats in the "advanced configuration". 
Select the length of the display: the fixed length of the output data, if it is less than the length, add 0 
before it, and discard it if it is greater than the length. 
Data output by the virtual keyboard car: After setting the previous parameters, the virtual keyboard 
output data is a reference. 
 

The software can intelligently and freely combine different output formats, which can 
be the output of decimal, hexadecimal and other data, and the output number 
According to the last line, when the " 

function selection

 " option selects to disable the 

virtual keyboard, it can be detected whether the data is correct, and select to enable 
When using the virtual keyboard, you can output data at the cursor position or in a 
text file like a keyboard. 

TID data reading mode: This mode adds the function of TID number output on the 

basis of EPC data reading mode. 
EPC+TID number output or TID output can be selected. As shown: 

 

                                               
 

Tag 

TID

 data encoding: represents the data in the TID block

 

 
 

4.2.5. 

Advanced settings

 

Advanced settings have higher professional knowledge for users, please consult 
customer service staff if you are unclear. 
Click the " 

advanced settings

 " button on the left , there are three sub-menus, 

namely 

basic parameters --- RF parameters --- other parameters

 

As shown: 

Summary of Contents for FC06

Page 1: ...UHF Desktop Reader User Manual...

Page 2: ...ns and dimensions 3 3 Wiring diagram 5 4 Software operation 6 4 1 Downloadlink 6 4 2 Operating instructions 7 4 2 1 Connecting equipment 7 4 2 2 Online 8 4 2 3 Demonstration of inventory 9 4 2 4 Simpl...

Page 3: ...ouse management and flow management of mail parcels and luggage Intelligent parking management parking management and automatic charging Production line management fixed identification of the producti...

Page 4: ...device otherwise the setting will fail Use the keyboard to output the RFID tag number type reference example Different manifestations of the same number Decimal value Dec 123456 Hexadecimal value Hex...

Page 5: ...the USB port of the computer and the following message will pop up Then open the computer Device Manager there will be an extra device in the Keyboard option as follows This means that the computer h...

Page 6: ...it Open the file and double click the software icon The following main interface appears 1 There are three kinds of communication parameter configuration we choose USB communication if the USB device...

Page 7: ...reboot the system As shown 4 2 3 Demonstration of inventory After the system is online the Inventory Demo interface will appear directly as shown in the figure above Put the RFID tag within the identi...

Page 8: ...ding mode and TID data reading mode Data writing mode When writing data to a single tag select this mode After entering this mode the device enters the command Status will not actively identify the la...

Page 9: ...ly combine different output formats which can be the output of decimal hexadecimal and other data and the output number According to the last line when the function selection option selects to disable...

Page 10: ...and does not send data to the communication interface need to send commands to receive data Same ID output interval the interval time for uploading the same tag data Buzzer can be turned on or off Au...

Page 11: ...e selected the frequency is hopped As shown Transmission power size the transmission power size range 0 30DBM the distance of the corresponding device to identify the RFID tag non line sex Radio frequ...

Page 12: ...number of boxes is a fixed number and can be modified arbitrarily Select the increment method of writing data there are increment and decrement the following column is the increment number Choose the...

Page 13: ...Copy Setting Description TID of This function is to directly copy the TID number of the tag to the EPC block data and turn it into the EPC number...

Reviews: