background image

Warning 

The LED units are Safety Extra Low Voltage and must not be earthed. 

Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Check the pack and make sure you have all the parts listed.
Install in accordance with the IEE Wiring regulations and current Building Regulations.
This system operates at Safety Extra Low Voltage (12V), via an LED driver. Never connect the light fittings directly to the mains
without using the supplied driver.
The mains plug must be situated indoors (e.g. house, garage, shed) in order to protect it from the elements.
Do not exceed the driver load. the supplied driver can operate up to a maximum of 20 LED heads.
Always disconnect the plug from the mains when installing or maintaining this system.
This system contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped.
The LED heads and driver are rated at IP67. They are suitable for installation in very wet areas, but must not be
permanently submerged.
The driver must not be installed directly in the soil.
Rated maximum surface temperature is 80ºC.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with

your local authority or retailer for recycling advice.

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory

operation of this product. Please retain these instructions for future reference. 

Layout

Plan the desired layout of these fittings carefully, ensuring the cables will reach the distances between the mains plug, the
LED driver and each light fitting.
Avoid locating any cables in positions that would cause a hazard. Position cables and driver away from areas where they may
be at risk from being cut, trapped or damaged.
The mains plug must be situated indoors. The kit can be wired into a IP67 external terminal block. This must be carried out by
a competent and qualified electrician.
Avoid locating any cables in positions that would cause a trip hazard. Position cables and driver away.
The driver and LED head units are rated at IP67 and can be positioned outdoors.
These fittings should not installed/mounted in concrete and should only be mounted in vertical surfaces
(only horizontally mounted).

Installation

This power supply is double insulated and does

not require connection to an Earth circuit.

1. Position the plug next to the indoor mains outlet socket that the system will connect to. Do not plug-in at this stage.
2. After deciding the layout of the light fittings, ensure the cables are long enough to connect to the desired positions.
   The maximum distance between heads is 1.5m.
3. Drill the mounting holes for the light units taking care not to damage any pipes or mains cables beneath the mounting
    surface. Cutter hole size is 25mm, Minimum hole depth is 80mm. 

(A)

4. From underneath the decking, feed the head unit and cable up through each installation hole. 

(B)

5. Fit the protective cap onto the head unit-to prevent the unit from dropping back through the holes and to keep debris out.
   Once the decking has been fully assembled and the lights are ready to be installed, remove the protective cap and push the
   LED unit onto the head unit observing the correct polarity (align the flat part of the connector to ensure correct connection). 

(C)

6. Fit the assembled head units into the holes by pushing into the hole. The springs on the side of the head will secure the
    head units in place. 

(D)

7. Connect all looms together and connect directly to the driver output cable, or the extension cable.
8. Ensure any unused heads and cable ends are fitted with the end plug and protective cap to prevent the ingress of moisture.
9. Plug the mains plug into the socket and switch on to test.    

Kit Layout Diagram

Kit includes:

This product is suitable for dimming with ‘SaxbySmart’ app, Google Home or Amazon Alexa. Please refer to the

‘SaxbySmart’ manual for specific operations.
We recommend putting the wifi receiver within 20-25 meters of your WI-FI Hub. This will vary depending on the

strength of your WI-FI coverage.
We recommend testing  the position before full installation.

   

Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully
note the position of each set of wires.
The Ikon Pro LED kit has been specifically designed for use in decking and combines some innovative features to make
installation easier. 2x prewired looms each with 5 LED heads plus a 5m extension cable allow longer runs to be achieved.
Wiring loom can be fitted into the deck during construction. Heads are interchangeable allowing different sizes and colours to
be operated from one power source.

A

B

C

D

10 x 0.75W LED HEADS
2 x 7.5m wiring looms,
1 x 5m extension cable,
1 x Inline LED driver with UK mains

plug & 3m of mains cable