Warning 

Please read these instructions carefully before commencing any work

This unit must be fitted by a competent and qualified electrician.

Install in accordance with the IEE Wiring regulations and current Building Regulations.

Check the pack and make sure you have all the parts listed.

To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons
cannot restore the electrical supply without your knowledge.

This light fitting should be connected to a fused circuit.

If replacing an existing fitting, make a careful note of the connections.

These products should not be fitted to PIR circuits or short duration timed switches.

This product is not suitable for dimming.

Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice.

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory

operation of this product. Please retain these instructions for future reference. 

Layout

This light fitting is double insulated and does

not require connection to an Earth circuit.

Plan the desired layout of these fittings carefully, ensuring the cables will reach the distances between each light fitting.

Avoid locating any cables in positions that would cause a hazard. Position cables away from areas where they may be
at risk from being cut, trapped or damaged

The mains supply cable must have a minimum cross section area of 1.0mm

2

.

This product is designed to be fitted into a suspended ceiling or wall mounted.

Installation

Exising fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully
note the position of each set of wires.
Note that the switch is turned off  before installation.
After deciding the layout of the light fittings ensure that the cables are long enough to connect to desired positions.  

• Undo two screws to remove the cover then open 4 clips with slotted screwdriver
   to separate the rear casing from the product. Keep screws in safe place for refitting later.

   
• Choose the cable entry hole on the rear casing and drill out the conduit knockout accordingly.
• This unit can be mounted on the wall or ceiling. After deciding the mounted way accordingly, Using the rear casing
   as a template mark the position to drill out the fixing holes. Take care to avoid damaging any concealed wiring and
   pipes. The correct fixings should be used, depending upon the surface to be mounted.
• Fix the rear casing into the position with the installation plugs and screws.
• Pull the cable through the cable entry hole and seal to maintain the IP rating. and wire as detailed Wiring Diagram.
•  Re-clip the front panel in place and re-secure the diffuser using the screws. Ensure that the seal is correctly fitted.
• Replace fuse or circuit breaker and switch on. Your light is now ready for use.

6

Wiring

• This product is double insulated and must not be earthed. If there are any incoming earth cables, they must be joined together

   and well insulated with good quality insulation tape. This is to ensure earth continuity throughout your property.
• Having correctly identified the wiring from your existing light fitting, connect to the quick fit connection block in the following

   way, using the supplied link cables where necessary.

LIGHT FITTING

SUPPLY

INSERT CABLE

PUSH DOWN

Check that...

•  You have correctly identified the wires.
•  The connections are tight.
•  No loose strands have been left out of the connection block.

PL

SL

N

LINK CABLE

Maintained (Unswitched) Wiring: The product is on
permanently and comes on during a power failure.

PERMANENT LIVE

NEUTRAL

BLUE(N)

BLACK(L)

BROWN(L)

LIGHT FITTING

SUPPLY

Non-Maintained Wiring:  The product is normally off and
comes on during a power failure.

PL

SL

N

PERMANENT LIVE

NEUTRAL

BLUE(N)

BLACK(L)

BROWN(L)

LIGHT FITTING

SUPPLY

Maintained (Switched) Wiring: The product is used as a
normal light - switch on/off, light turns on/off. comes on
during a power failure.

PL

SL

N

PERMANENT LIVE

NEUTRAL

BLUE(N)

BLACK(L)

BROWN(L)

SWITCH LIVE

LIGHT FITTING

SUPPLY

1

2

or

or

or

3

140mm

4

5

See Wiring
diagram