Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and
satisfactory operation of this product. Please retain these instructions for future reference.
Warining
Technical data
Please read these instructions carefully before
commencing any work.
Cables must be protected using suitable conduit
or plastic trunking.
Waste electrical products should not be disposed
of with household waste. Please recycle where
facilities exist. Check with your local authority or
retailer for recycling advice.
This unit must be fitted by a competent and
qualified electrician.
Check the pack and make sure you have all of the
parts
listed.
To prevent electrocution switch off at mains supply
This light fitting should be connected to a circuit
with a 30mA RCD fitted.
before installing or maintaining this fitting.
Ensure other persons cannot restore the electrical
supply without your knowledge.
Install in accordance with IEE Wiring regulations
and current Building Regulations.
Supply
Bulb Type:
Voltage:
240 V~, 50 Hz
LED (18 W) SMD 2835D 1650lm 6500K - (75531)
LED (36 W) SMD 2835D 3300lm 6500K - (75532)
LED (45 W) SMD 2835D 4000lm 6500K - (75533)
LED (55 W) SMD 2835D 6000lm 6500K - (75534)
The light source of this luminaire is not replaceable; when the light source reaches its end of life
the whole luminaire shall be replaced.
Conformity with all relevant EC Directive requirements.
The power supply is Double Insulated and does not require connection to an Earth circuit.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist.Check with your Local Authority or
local store for recycling advice.
This product is not suitable for dimming.
Caution! Risk of electric shock!
This product is rated at IP65.
Installation
Max number of interconnect with model: 15 pcs -(75531) / 12pcs -(75532)
12 pcs -(75533) / 8pcs -(75534)
Existing fittings must be completely removed before installation of a new product. Before removing the
existing fitting, carefully note the position of each set of wires.
•
The ceiling surface must be flat and smooth to ensure a good fit.
•
Note that the switch is turned off before installation.
•
Attach product to mounting brackets by pushing until
securely held.
•
Plan the desired layout of this fitting carefully, ensuring the cables will reach the distance between the
junction box and the light fitting.
•
Avoid locating any cables in positions that would cause a hazard. Position cables and outdoor rated
junction boxes (not supplied) away from areas where they may be at risk from being cut, trapped
or damaged.
•
Refer to the diagram below. Decide on the location of
the product. Measure the distance between the
mounting bracket location slots, mark the location
of the fixing holes on the mounting surface.
•
Drill holes and fit supplied wall plugs (suitable for
masonry only - for other surfaces use appropriate
fixings).
IP65
We recommend that you use H05RN-F specification
cable (not supplied) which is an outdoor grade,
rubber sheathed cable. The mains supply cable
must have a minimum cross sectional area
of 1.0mm²
If replacing an existing fitting, make a careful note
of the connections.
1
2
Model
H1
H2
L
W
A
665mm
1265mm
74mm
74mm
42.5mm 300±10mm
900±10mm
49mm
1565mm 74mm
1200±10mm
75531
75532
75533/75534
42.5mm
49mm
42.5mm
49mm
W
H1 H2
A
L
“click”
“click”
“click”
H05RN-F 2G 1,0 mm²
“click”
not provided
The side that doesn’t have a wire
must be plugged with plastic cap.
Prevent water ingress.