background image

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 
satisfactory operation of this product. Please retain these instructions for future reference.

Warning

This is a Class 1 product and must be earthed.

Please read these instructions carefully before 
commencing any work.

This unit must be fitted by a competent and qualified 
electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure 
other persons cannot  restore the electrical supply 
without your knowledge. If you are in any doubt, 
please consult a qualified electrician.

If replacing an existing fitting, make a careful note of 
the connections.

Waste electrical products should not be disposed of 
with household waste. Please recycle where facilities 
exist. Check with your local authority or retailer for 
recycling advice.

This product is rated at IP20.

This light fitting contains non-replaceable parts and 
cannot be serviced.

If damage occurs the part should be discarded.

This product is not dimmable.

The installation of this fitting will be much easier with 
the help of an assistant.

Specification

Voltage: 

240V 50Hz a.c.

Lamp: 

14W LED Module (4000K/1060lm) 

   

IP rating: 

20

Layout

•  Ensure the ceiling is capable of holding the weight of 

the product.

•  Plan the desired layout of this fitting carefully, 

ensuring the cables will reach the distance between 
the junction box and light fitting.

•  The mains supply cable must have a minimum cross 

sectional area of 1.0mm

2.

Existing fittings must be completely removed before 
installation of a new product. Before removing the 
existing fitting, carefully note the position of each set 
of wires
.

•  See Fig. 1. This product has two outer ceiling fixing 

points. Check and measure the distance for the fixing 
holes so the fixing cables hang vertically. Optimum 
distance between suspension cables is 1100mm. 
Ensure the ceiling is capable of holding the weight of 
the product. Take care to avoid damaging any wiring or 
pipes. Drill the holes and fit the supplied wall plugs.

•  See Fig. 1. Attach the suspension cables to the ceiling 

by unscrewing the top cable fixing (1) and placing the 
screw through the hole. Screw into wall plug in the 
ceiling. Reattach the bottom section (2) of the top cable 
fixing and tighten to secure in place.

 • See Fig. 2. Fit the suspension cables to the product 

by attaching the lower cable fixing (3) in place. Simply 
screw the lower cable fixing onto the threaded rods at 
each end of the pendant. To adjust the height of the 
fitting, depress the button (4) located on the lower cable 
fixing. Please ensure the suspension cable protrudes 
at least 10mm from the lower cable fixing. Ensure that 
both suspension cables are adjusted to the same length 
so the product hangs level.

•  See Fig. 3. Decide on the location of the fixing bracket. 

Mark the position of and drill the fixing holes. Take care 
to avoid damaging any wiring or pipes. Attach the fixing 
bracket to the ceiling with the suppled wall plugs and 
screws.

•  Wire as detailed below.

Installation

Wiring

Check that...

•  You have correctly identified the wires
•  The connections are tight

•  No loose strands have been left out of the connection 

block.

Having correctly identified the wiring from your existing light fitting, connect to the connection block inside the 
product in the following way:

Fig. 1

Fig. 2

Fig. 3

1

2

3

4

Reviews: