Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and
satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This is a Class 1 product and must be earthed
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure
other persons cannot restore the electrical supply
without your knowledge.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of
the connections.
This system contains non-replaceable parts and
cannot be serviced. If damage occurs the part should
be scrapped.
This product is not suitable for dimming.
This product is rated at IP44.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.
Specification
Voltage:
240V 50Hz a.c.
Lamp:
10W LED (SMD 2835) - 23lm per LED (144 in total)
IP rating:
44
Layout
• Plan the desired layout of this fitting carefully,
ensuring the cables will reach the distance between
the junction box and the light fitting.
• Cables in walls must be protected using suitable
conduit or plastic trunking.
• The mains supply cable must have a minimum cross
sectional area of 1.0mm².
• This product has special protection against the
ingress of moisture and is IP44 rated.
• This product is fitted with a no touch infra-
red switch, helping to keep the mirror clear of
fingerprints. To operate, simply wave your hand in
front of the sensor.
Existing fittings must be completely removed before
installation of a new product. Before removing the
existing fitting, carefully note the position of each set
of wires.
• The installation of this product will be easier with the
help of an assistant.
• Using the hole spacing dimensions detailed below,
mark and drill the fixing holes. Take care to avoid
damaging any concealed wiring or pipes. Fit the wall
plugs and supplied screws. Ensure the screw heads
protrude from the wall around 3mm as shown in Fig
A. Ensure the screw holes are accurately located in
the wall, as the mirror will hang from the screws.
• Wire as detailed overleaf.
Installation
This product is suitable for use in Zone
2 and outside Zones of a bathroom.
See diagram. If this unit is being
fitted in a room containing a bath or
shower, a 30mA RCD must be used,
in accordance with IEE regulations.
445
500
Hole Spacing Dimensions
Fig. A