Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
Technical data
Please read these instructions carefully before
commencing any work.
Ensure that the supplied transformer is used.
The product is designed to be fitted horizontally and
vertically in decking, walls, steps etc. It is not suitable
for installation directily into the ground
This unit must be fitted by a competent and
qualified electrician.
Check the pack and make sure you have all of the
parts listed.
This system operates at Safety Extra Low Voltage
(12V), via a transformer. Never connect the light
fittings directly to the mains without using a
transformer.
Install in accordance with IEE Wiring regulations
and current Building Regulations.
Supply
Bulb Type:
Voltage:
240V~, 50 Hz
LED (10 x 0,45W) 6500K
The light source of this luminaire is not replaceable; when the light source reaches its end of life the
whole luminaire shall be replaced. Do not stare at the operating light source.
Conformity with all relevant EC Directive requirements.
Waste electrical products should not be disposed of with household waste.
Class III product - designed to be supplied from a SELV
(Separated or Safety Extra-Low Voltage) power source.
Class II product - Double Insulated - No earth required.
Please recycle where facilities exist.Check with your Local Authority or
local store for recycling advice.
This product is not suitable for dimming.
Splash-proof
Installation
Existing fittings must be completely removed before installation of a new product. Before removing the
existing fitting, carefully note the position of each set of wires.
•
Note that the switch is turned off before installation.
•
Plan the desired layout of these fittings carefully, ensuring the cables will reach the distances between
the indoor transformer and each light fitting.
•
Avoid locating any cables in positions that would cause a trip hazard. Position cables away from areas
where they may be at risk from being cut, trapped or damaged.
•
Maximum distance between heads is 800mm.
•
Ensure the connectors are accessible for future maintenance.
•
The plug-in transformer has no special protection against moisture and must be situated indoors.
•
The light units are rated at IP44. Avoid positioning head units and conectors in very wet areas.
•
Position the plug- in transformer next to the indoor mains outlet socket that the system will connect to.
Do not plug-in at this stage.
•
After deciding the layout of the light fittings, ensure the cables are long enough to connect to the desired
positions.
•
Drill the mounting holes for the light units taking care not to damage any pipes or mains cables beneath
the mounting surface. These require a 22mm clearance hole.
•
Feed the plug and cables of each light unit through the mounting holes and push unit into the hole to secure.
•
Connect each LED light to the next LED light ensuring the arrows on connectors are facing each other and
all plugs are fully fitted into the sockets. See Connectors Drawing below.
•
Connect the extension cable to the transformer.
•
Plug the transformer into the mains socket and switch on.
IP44
The mains plug must be situated indoors (e.g. house,
garage, shed) in order to protect it from the elements.
BS Plug-in LED driver Rico Electronic
Model: RKP-UK1200500DP-1
Input: 100-240V~, 50/60 Hz
Output: CV 12 V, 500 mA 6W max IP20 TUV CE approved
Do not exceed the transformer load. Transformers
may require a minimum load to operate.
Always disconnect the transformer from the mains
when installing or maintaining this system.
This system contains non-replaceable parts and
cannot be serviced. If damage occurs the part
should be scrapped.
800mm Max
End cap
30mm diameter LED
22mm diameter
mounting hole
(minimum 30mm depth)