background image

www.saxbylighting.com

Instruction manual

95544

Hero CCT Step Dimming Emergency

Saxby Lighting. BH17 7BY

V1 16/01/2021

We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.

For your safety, always switch off the power supply before cleaning.

Care and Safety

Stepped Dim Microwave Movement Sensor

This product is fitted with a stepped dim microwave movement sensor. Please see below detailed operating instructions.

MULTI-FUNCTION SENSOR SPECIFICATIONS:

DC Input Voltage 

 

12±1V DC

Rated Voltage 

 

12±0.6V DC 

Efficiency  

 

80%

Stand-by Power 

 

<0.5W

Operating Frequency 

 

5.8 GHz ±75 MHz

Transmitting Power 

 

0.5mW Max.

Hold Time   

 

5s / 90s / 3min / 10min

Stand-by DIM Level 

 

20%

Stand-by Period 

 

0s / 30s /10min / +

Detection Area 

 

100% / 75% / 50% / 25%

Daylight Sensor 

 

5Lux / 15Lux / 50Lux / Disable

Detecting Radius 

 

5m (mounting height 3m)

Mounting Height 

 

4m Max

Detecting Angle 

 

150º

Operating Temperature   

-25ºC…+60ºC

   Temperature: 

-40ºC…+80ºC; 

 

 

 

Humidity: 10% - 95% (non-condensing)

Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and
walking speed is 0.3m/s.

Storage Temperature

FUNCTION:

1) On/OFF function (stand-by period be set to “0”s)

With sufficient ambient

light, the light will not be

switched on even if with

motion signal. 

With insufficient ambient

light, the sensor switches

on the light when motion

is detected.

After elapse of hold time, the

sensor switches off the light

when no motion is detected.

after elapse of standby period, 

the sensor switches off the

light if no motion is detected

in the detection zone.

2) step dimming function (stand-by period be set to “+

”)

If there is no motion

detected, the light will be

remained at a low light

level all the time.

When motion is detected,

the sensor will switch on the

light to 100% brighteness.

After elapse of hold time, the

sensor dims the light at the

present low light leven if no

motion is detected.

3) step dimming function (stand-by period be set to “10s / 1min / 3min / 5min / 10min / 30min”)

With sufficient ambient

light, the light will not be

switched on even if with

motion signal. 

With insufficient ambient

light, the sensor switches

on the light when motion

is detected.

After elapse of hold time, the

sensor dims the light at a low

light leven if no new motion

is detected.

1 2

100%

75%
50%
25%

1. Detection Area

This determines the effective range of the motion

detector and is set up by DIP switches at the

sensor. Note that reducing the sensitivity will

also narrow the detection range.

  I –100%
 II –  75%

III –  50%

IV –  25%

3 4

5s
90s
3min
10min

This determines the time the fitting remains at

100% level on motion detection and is set with

 DIP switches at the sensor. The walk test setting

 is useful when installing the fitting to establish

 correct operation and range. 

  I –  

5s

 II –  

90s

III –  

3min

IV –  

10min

2. Hold Time

5 6

+

50Lux
15Lux
5Lux

This setting holds off the 100% light output

should there be sufficient daylight and is

set using DIP switches at the sensor.

  I – 

+

 II –  

50Lux

III –  

15Lux

IV –  

5Lux

3. Daylight Sensor

7 8

0s

30s
10min

+

This setting determines how long the fitting

should operate at 10% output after the hold

time has elapsed and is set by DIP switching

at the sensor.

  I –  

0s

 II –  

30s

III –  

10min

IV –  

+

4. Stand-by Period

DIP SWITCH SETTING:

Reviews: