Care and Safety
Stepped Dim Microwave Movement Sensor
This product is fitted with a stepped dim microwave movement sensor. Please see below detailed operating instructions.
MULTI-FUNCTION SENSOR SPECIFICATIONS:
DC Input Voltage
12±1V DC
Rated Voltage
12±0.6V DC
Efficiency
≥
80%
Stand-by Power
<0.5W
Operating Frequency
5.8 GHz ±75 MHz
Transmitting Power
0.5mW Max.
Hold Time
5s / 90s / 3min / 10min
Stand-by DIM Level
20%
Stand-by Period
0s / 30s /10min / +
∞
Detection Area
100% / 75% / 50% / 25%
Daylight Sensor
5Lux / 15Lux / 50Lux / Disable
Detecting Radius
5m (mounting height 3m)
Mounting Height
4m Max
Detecting Angle
150º
Operating Temperature
-25ºC…+60ºC
Temperature:
-40ºC…+80ºC;
Humidity: 10% - 95% (non-condensing)
Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and
walking speed is 0.3m/s.
Storage Temperature
FUNCTION:
1) On/OFF function (stand-by period be set to “0”s)
With sufficient ambient
light, the light will not be
switched on even if with
motion signal.
With insufficient ambient
light, the sensor switches
on the light when motion
is detected.
After elapse of hold time, the
sensor switches off the light
when no motion is detected.
after elapse of standby period,
the sensor switches off the
light if no motion is detected
in the detection zone.
2) step dimming function (stand-by period be set to “+
∞
”)
If there is no motion
detected, the light will be
remained at a low light
level all the time.
When motion is detected,
the sensor will switch on the
light to 100% brighteness.
After elapse of hold time, the
sensor dims the light at the
present low light leven if no
motion is detected.
3) step dimming function (stand-by period be set to “10s / 1min / 3min / 5min / 10min / 30min”)
With sufficient ambient
light, the light will not be
switched on even if with
motion signal.
With insufficient ambient
light, the sensor switches
on the light when motion
is detected.
After elapse of hold time, the
sensor dims the light at a low
light leven if no new motion
is detected.
1 2
100%
75%
50%
25%
1. Detection Area
This determines the effective range of the motion
detector and is set up by DIP switches at the
sensor. Note that reducing the sensitivity will
also narrow the detection range.
I –100%
II – 75%
III – 50%
IV – 25%
3 4
5s
90s
3min
10min
This determines the time the fitting remains at
100% level on motion detection and is set with
DIP switches at the sensor. The walk test setting
is useful when installing the fitting to establish
correct operation and range.
I –
5s
II –
90s
III –
3min
IV –
10min
2. Hold Time
5 6
+
∞
50Lux
15Lux
5Lux
This setting holds off the 100% light output
should there be sufficient daylight and is
set using DIP switches at the sensor.
I –
+
∞
II –
50Lux
III –
15Lux
IV –
5Lux
3. Daylight Sensor
7 8
0s
30s
10min
+
∞
This setting determines how long the fitting
should operate at 10% output after the hold
time has elapsed and is set by DIP switching
at the sensor.
I –
0s
II –
30s
III –
10min
IV –
+
∞
4. Stand-by Period