Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
This is a Class 1 product and must be earthed.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure other
persons cannot restore the electrical supply without your
knowledge.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of the
connections.
Always use the correct type and wattage bulb. Exceeding
the bulb wattage will damage the product.
When changing a bulb, always switch off at the mains and
allow the old bulb to cool down before handling. Dispose
of used bulbs carefully and responsibly.
This product is suitable for dimming when used in
conjunction with a dimmable lamp. Please ensure
verification of dimming abilities with the lamp
manufacture prior to use.
Specification
Voltage:
240V 50Hz a.c.
Lamp:
4 x 50W GU10 Halogen
IP rating:
20
Layout
Existing fittings must be completely removed before
installation of a new product. Before removing the existing
fitting,
carefully note the position of each set of wires
.
• Undo the screws (1) holding the fixing bracket in place
and set aside.
• Hold the bracket (2) in place and mark the position of
the holes. Ensure that the product is level.
• Ensure the ceiling is capable of holding the weight of
the product. Take care to avoid damaging any concealed
wiring and pipes. Ensure there is a joist at the point of
fixing to support the weight of the product.
Installation
Wiring
Having correctly identified the wiring from your existing light
fitting, pull the wire through the hole and connect to the
connection block inside the product in the following way:
Check that...
• You have correctly identified the wires.
• The connections are tight.
• No loose strands have been left out of the connection
block.
• When completed, ensure that there are no bare or loose
strands of wire exposed, and cover all exposed areas of
the connection block with 2 layers of insulation tape.
• Plan the desired layout of this fitting carefully, ensuring
the cables will reach the distance between the junction
box and the light fitting.
• Avoid locating any cables in positions that would cause
a hazard. Position cables and junction boxes (not
supplied) away from areas where they may be at risk
from being cut, trapped or damaged.
• The mains supply cable must have a minimum cross
sectional area of 1.0mm².
• This product must be mounted out of arms reach.
SUPPLY
NEUTRAL
LIGHT FITTING
BLUE (N)
EARTH (GREEN/YELLOW)
GREEN/YELLOW
BROWN (L)
SWITCHED LIVE
FOURTH TERMINAL BLOCK PROVIDED
FOR LOOP TERMINATION IF NECESSARY
0.5m
Spotlights give a concentrated beam of light and must not be positioned any closer than 0.5M (50cm) to
the illuminated surface.