background image

Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory 
operation of this product. Please retain these instructions for future reference.

Warning

This is a Class 1 product and must be earthed.

Please read these instructions carefully before 
commencing any work. 

This unit must be fitted by a competent and qualified 
electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure other 
persons cannot  restore the electrical supply without your 
knowledge.

This light fitting should be connected to a fused circuit.

If replacing an existing fitting, make a careful note of the 
connections.

Always use the correct type and wattage bulb. Exceeding 
the bulb wattage will damage the product.

When changing a bulb, always switch off at the mains and 
allow the old bulb to cool down before handling.  Dispose 
of used bulbs carefully and responsibly.

This product is suitable for dimming when used in 
conjunction with a dimmable lamp. Please ensure 
verification of dimming abilities with the lamp 
manufacture prior to use.

Specification

Voltage: 

240V 50Hz a.c.

Lamp: 

4 x 50W GU10 Halogen

IP rating: 

20

Layout

Existing fittings must be completely removed before 
installation of a new product. Before removing the existing 
fitting, 

carefully note the position of each set of wires

.

•  Undo the screws (1) holding the fixing bracket in place 

and set aside.

•  Hold the bracket (2) in place and mark the position of 

the holes. Ensure that the product is level.

•  Ensure the ceiling is capable of holding the weight of 

the product. Take care to avoid damaging any concealed 
wiring and pipes. Ensure there is a joist at the point of 
fixing to support the weight of the product. 

Installation

Wiring

Having correctly identified the wiring from your existing light 
fitting, pull the wire through the hole and connect to the 

connection block inside the product in the following way:

Check that...

•  You have correctly identified the wires.
•  The connections are tight.
•  No loose strands have been left out of the connection 

block.

•  When completed, ensure that there are no bare or loose 

strands of wire exposed, and cover all exposed areas of 
the connection block with 2 layers of  insulation tape.

•  Plan the desired layout of this fitting carefully, ensuring 

the cables will reach the distance between the junction 
box and the light fitting.

•  Avoid locating any cables in positions that would cause 

a hazard. Position cables and junction boxes (not 

supplied) away from areas where they may be at risk 
from being cut, trapped or damaged.

•  The mains supply cable must have a minimum cross 

sectional area of 1.0mm².

•  This product must be mounted out of arms reach.

SUPPLY

NEUTRAL

LIGHT FITTING

BLUE (N)

EARTH (GREEN/YELLOW)

GREEN/YELLOW

BROWN (L)

SWITCHED LIVE

FOURTH TERMINAL BLOCK PROVIDED 
FOR LOOP TERMINATION IF NECESSARY

0.5m

Spotlights give a concentrated beam of light and must not be positioned any closer than 0.5M (50cm) to 
the illuminated surface.

3

Reviews: