Warning
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Installation
This product is double insulated and does
not require connection to an Earth circuit.
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting,
carefully
note the position of each set of wires
.
Note that the switch is turned off before installation.
Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.
After deciding the layout of the light fittings ensure that the cables are long enough to connect to desired positions.
•
Undo the screw at the bottom of the product to separate the rear panel from product. Keep screw in safe place for
refitting later.
•
If you wish to pass the mains cable through the rear panel, drill through the cable entry hole (bottom right when rear
panel is attached to wall) and make sure the rubber grommet supplied in the fixing pack is in place to ensure ingress
protection. Alternatively, the mains cable can be passed through the cable entry hole on the underside of the product.
Again, use the supplied grommet to ensure ingress protection.
• Using the rear panel as a template, mark and drill the fixing holes (diagonally positioned). The fixing holes are marked out in
the rear panel-drill through them too. Make sure the rear panel is correctly oriented with the straight edge at the bottom.
Take care to avoid damaging any concealed wiring or pipes.
• Fix the bottom with inflated screw on the selected position. install back the sensor on the bottom,
tighten the screw and then test it.
• Wire as detailed below.
Having correctly identified the wiring from your existing light fitting and connect to the connection block inside the product in
the following way:
Wiring
Check that...
You have correctly identified the wires
The connections are tight
Layout
This product is designed for optimum performance when mounted 1.8-2.5m above the ground.
Avoid pointing the detector towards objects with highly reflective surfaces, such as mirrors etc.
Avoid mounting the detector near heat sources, such as heating vents, air conditioning units, light etc.
Avoid pointing the detector towards objects that may move in the wind, such as curtains, tall plants etc.
The mains supply cable must have a minimum cross section area of 1.0mm
2
.
Cables must be protected using suitable conduit or plastic trunking.
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons cannot
restore the electrical supply without your knowledge.
If you are in any doubt, please consult a qualified electrician.
If replacing an existing fitting, make a careful note of the connections.
This unit should be connected to a fused circuit.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice.
This product is double insulated and must not be earthed. If there are any incoming earth cables, they must be joined together
and well insulated with good quality insulation tape. This is to ensure earth continuity throughout your property.
No loose strands have been left out of the connection block
The cable clamp is fitted over the wires.
IN
OUT
L
N
IN~
OUT~
LOAD
L(BROWN)
N(BLUE)
A(RED)
PIR