The heater can be placed wherever in the sauna, but for safety and
convenience, follow the minimum safety distances as provided in Fig. 2. Follow
the cubic volumes given in the Technical Diagram (page 12.). Do not install the
heater to the floor or wall niche. Do not install more than one heater in a
sauna room unless you follow the special instructions for twin-heater
installations. In most countries, there is a law that requires heaters to be
screwed to the floor as provided in Fig. 1a. Install bracket support for safety
purposes Fig. 1b.
The heater gets very hot. To avoid the risk of accidental contact with the
heater, it is recommended that a heater guard be provided.
The cable used for sauna wiring must be HO7RN-F type or its equivalent. A
certified electrician must do the installation of the heater to ensure safety and
reliability. Improper electrical connection can cause electric shock or fire. Refer
to the electrical diagram in page 6.
Heater Installation
Mindest Sicherheitsabstände (mm)
Minimum Safety Distances (mm)
Abb. 2
Fig. 2
A
A
B
20
100
max. 500
DEUTSCH / ENGLISH
3
NOTE:
Please refer to the control unit
manual for maximum power rating.
Contactor unit is needed if heater’s
power rating exceeds separate
control unit’s capacity. Additional
contactor unit can be connected to
the heaters 10,5kW and higher.
100
100
100
100
150
200
1900
1900
1900
1900
1900
2100
TH6-80NB
TH6-90NB
TH6-80NS
TH6-90NS
TH6-105N
TH6-120N
A
B
150
150
200
200
200
200
200
200
2100
2100
2100
2100
2300
2300
2300
2300
TH9-105N
TH9-120N
TH9-150N
TH9-180N
TH12-150N
TH12-180N
TH12-210N
TH12-240N
A
B
A
B
150
150
200
200
150
200
200
200
150
150
200
200
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
1900
TH2-30NB
TH3-35NB
TH3-45NB
TH3-60NB
TH2-30NS
TH3-35NS
TH3-45NS
TH3-60NS
TH4-60NB
TH4-60NS
TH4-80NS
TH5-90NS
HINWEIS:
Die maximale Leistung entnehmen
Sie bitte der Bedienungsanleitung
für die Steuerung. Wenn die
Leistung
des
Ofens
die
Leistungsstärke
der
separaten
Steuerung überschreitet, wird ein
Leistungsschütz benötigt. Weitere
Leistungs-Schütze können bei den
Öfen mit 10,5kW oder höher
angeschlossen werden.