DIAGNOSTIC TABLE
If heater is not heating up or sauna room is heating up slowly:
NB-MODELS:
•
Is timer set to the operating range?
•
Is the timer On? Is timer knob stuck? (Suitable gab is 1 - 2mm between knob and
heater body) If necessary, pull out the knob couple of millimeters.
•
Is the thermostat set to higher than temperature inside the sauna room?
•
Is the temperature fuse defective? Find out the reason before turning on your
heater again.
•
Are all heating elements glowing red when the heater is ON?
•
Is the heater’s heating power enough for the sauna room? (See page 11)
•
Are the sauna stones laid properly? Is there enough space for air circulation and
stones are in good condition? If stones are laid loosely, sauna will warm up faster.
•
Is the air circulation enough in the sauna room? (See page 21)
NS- AND NI-MODELS:
•
Is the control unit ON?
•
Is the set temperature higher than the temperature inside the sauna room?
•
Is the main switch ON? In Ni-models, main switch is located at the bottom of the
heater, and in NS-models it is on the power control.
•
Are the switchboard fuses ON and unbroken? If broken, find out the reason before
turning ON your heater.
•
Are all heating elements glowing red when the heater is ON?
•
Is the heater’s heating power enough for the sauna room? (See page 11)
•
Are the sauna stones laid properly? Is there enough space for air circulation and
stones are in good condition? ? If stones are laid loosely, sauna will warm up faster.
•
Is the air circulation enough in the sauna room? (See page 21)
IF THE SURFACES DARKEN AROUND THE HEATER:
•
Is the heater installed following the safety distances? (See page 10)
•
Have you laid the sauna stones correctly and there is enough space between the
stones for air circulation? If air circulation is blocked constructions around the
heater might over heat.
•
Are the heating elements visible behind the stones? Re-lay if necessary.
•
If you cannot find the reason, contact your retailer.