Errors and possible remedies
5.1
Automatic time limitation
The sauna control turns off after 6 / 12 hours of
continuous heating (depending on factory set-
ting).
For continued operation press the START /
STOP
8
key.
5.2
Interior lighting does not work
Turn off ON / OFF
1
key.
Turn off main fuse of the sauna control in the
fuse box.
Replace light bulb.
Contact customer service or the electrical engi-
neer, if the interior light still does not work. (look
at part 1, chapter 6)
5.3
ERROR Display messages
The sauna control is not ready-to-operate:
1. Turn off main fuse of the sauna control in the
fuse box.
2. Contact customer service or the electrical engi-
neer.
3. Mark the device as defective.
Operating instructions for the user - Figure
5
5
Errors and possible remedies
With the following display error messages
4
you
can inform customer service of possible errors/de-
fects.
The error messages of the display mean:
E-F1:
Short-circuit or interrupted tempe
rature sensor line (white line)
E-24:
Excessive temperature fuse defect,
or (red) cable to excessive
temperature fuse interrupted.
E-P1:
Setting potentiometer for nominal
temperature defect.
E-51; E-52;E-53:Key
7
or
8
blocked
LL:
Temperature of interior
below 0°C
HH:
temperature of interior
above 140°C