hEatEr installation
The heater can be placed wherever in the sauna, but for safety and convenience, follow
the minimum safety distances as provided below (See page 9). Follow the cubic
volumes given in the Technical Data (See page 34). Do not install the heater to the
floor or wall niche. Do not install more than one heater in a sauna room unless you follow
the special instructions for twin-heater installations. In most countries, there is a law that
requires heaters to be screwed to the floor.
The heater gets very hot. To avoid the risk of accidental contact with the heater, it is
recommended that a heater guard be provided.
The cable used for sauna wiring must be HO7RN-F type or its equivalent. A certified
electrician must do the installation of the heater to ensure safety and reliability. Improper
electrical connection can cause electric shock or fire. Refer to the electrical diagram (See
page 16).
notE!
Please refer to the control unit manual
for maximum power rating.Contactor
unit is needed if heater’s power rating
exceeds separate control unit’s capacity.
Additionalcontactor unit can be connected
tothe heaters 10,5kW and higher.
huom!
Tarkista ohjauskeskuksen tehonkesto
ohjauskeskuksen käyttöohjeesta.
Kontaktoriyksikkö tarvitaan, jos kiukaan
teho ylittää erillisen ohjauskeskuksen
kapasiteetin. Erillinen kontaktoriyksikkö
voidaan liittää kiukaisiin joiden teho on
10,5kW tai enemmän.
Minimum safety distances (mm)
Vähimmäisetäisyydet (mm)