Document n° 986-1 ~ 02/07/1999
Multifuel stove
"SAVOY"
Réf. : 134 08 05
Technical manual
Page 1: ... Warranty certificate Technical manual to be saved by the user for future reference Document n 986 1 02 07 1999 Fonderies FRANCO BELGES 59660 MERVILLE Phone 03 28 43 43 43 Fax 03 28 43 43 99 RC Hazebrouck 445750565B Subject to modifications SAVOY Multifuel stove Model 134 08 05 Output 8 kW ...
Page 2: ...onnection to flue 4 Assembly of flue spigot and blanking plates 5 Door closing pressure 6 Mounting the tray 6 Chimney maintenance and sweeping 6 Instructions for user 7 Fuel 7 Lighting 8 Re fuelling 8 Cleaning 8 Maintenance of the stove body 8 Trouble Shooting 9 Spare parts 11 Page Document n 986 1 02 07 1999 Multifuel stove SAVOY Réf 134 08 05 2 Technical manual ...
Page 3: ...kg 100 Volume heated m3 300 Autonomy h 10 1 4 Description Multifuel stove Fuel burnt on grate Removable appliance to be installed near a wall Detachable flue spigot for rear or top chimney connection Detachable top for easy handling and cleaning rear smoke exit only Adjustable air controls for controlling the burning rate Spin wheel for lighting Large ash pan 1 5 Principle of operation The Savoy i...
Page 4: ...ible causing condensation problems tar formation etc to occur The flue must not be shared with other appliances The recommended minimum flue height is 5 meters If the chimney has any down draught tendency due to its position in relation to nearby obstacles then an anti down draught cowl must be installed on the chimney or the chimney height must be increased If the decompression in the chimney is ...
Page 5: ... the retainer fuel fig 7 p 6 the two side bricks 23 and 24 p 10 and the flue baffle fig 8 p 6 Remove the blanking plate 3 and the clamp 4 and assembly in the top ensuring there is a good seal Fix the flue collar 1 at rear with 3 bolts and washers supplied ensuring there is a good seal Remove the cut out in the rear heat shield and re fit Replace top plate 1 2 3 4 2 5 Figure 2 Flue outlet on the to...
Page 6: ...e and sweeping Very important To avoid accidents chimney fire etc regular maintenance should be carried out If the stove is regularly used the chimney should be swept several times per year together with the stove pipe connection section First remove the retainer grate fig 7 the two side bricks 23 24 p 10 and the flue baffle fig 8 Chimney condition should be checked at least once per year A Figure...
Page 7: ...The best fuels for use with the Franco Belge Savoy are Smokeless fuels including coolite nuts phurnacite ancit extracite and pureheat Sunbrite Small Anthracite Medium Dry Wood Use hard wood logs which have been cut for at least two years and stored under shelter Hardwood has a higher calorific value per cu metre oak ash maple birch elm beech etc Prohibited fuel Homefire and any form of bituminous ...
Page 8: ...HE ASH PIT AREA THROUGH THE GRATE AND THROUGH THE FUEL IF THE GRATE OR ASH PAN ARE CONGESTED THE PERFORMANCE WILL BE EFFECTED If burning solid fuel always empty the ash pan at least once a day or whenever it is full of ashes Never allow the ashpan to overfill allowing ash to be in contact with the underside of the grate If this condition is allowed the grate will wear out pre maturely 3 5 Maintena...
Page 9: ...continuously burn small wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up Flue duct is cold Burn paper and kindling wood to increase heat Room is in decompression In houses equipped with mechanical ventilation partly open a window until the fire is well established Smokes while burning Draught is insufficient þ Consult a chimney specialist Check that the flue is not...
Page 10: ...4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 2 3 8 8 32 17 17 17 40 Document n 986 1 02 07 1999 Multifuel stove SAVOY Réf 134 08 05 10 Technical manual ...
Page 11: ... 13 222556 Flue baffle 01 14 237411 EF Reducing plate 01 15 259015 Fixing plate 04 16 270408 Air control flap 01 17 300127 EF Leg 04 18 300481 EF Base 01 19 301526 EF Door lock 01 20 301742 EF Air damper 01 21 303718 EF Blanking plate 01 22 303860 EF Flue collar 01 23 305014 Wall 01 24 305212 Wall 01 25 306276 EF Back wall 01 26 307434 EF Fuel retainer 01 27 308711 Coal grate 01 28 309891 EF Front...
Page 12: ... in our instructions Parts which are damaged by external causes such as unadapted chimneys thunderstorms damp faulty pressure or fail in pressure thermic anomalies explosions etc Electrical parts which are deteriorated by any connection or use on a supply circuit with voltage within 10 of the indicted voltage 230 V Material subject to modifications without prior notice This manual does not engage ...