4. MOUNTING OPTIONS

If there isn't an existing UL listed mounting 
box, then read the following instructions. 
Disconnect the power by removing fuses or 
turning off circuit breakers.

Secure the outlet box directly to the building 
structure. Use appropriate fasteners  and 
building materials. The outlet box and its 
support must be able to fully support the 
moving weight of the fan (at least 50 lbs).  Do 
not use plastic outlet boxes.

Figures 1, 2 and 3 are examples of different 
ways to mount the outlet box.

Note:

 You may need a longer downrod to 

maintain proper blade clearance when 
installing on a steep, sloped ceiling. (Fig. 3)

To hang your fan where there is an existing 
fixture but no ceiling joist, you may need an 
installation hanger bar as shown in Figure 4.

Outlet box

Provide strong
support

Recessed
outlet box

Ceiling
mounting
plate

Outlet  box

Figure 1

Figure 3

Figure 4

Outlet box

Figure 2

3

ANGLED CEILING

MAXIMUM 25° ANGLE

Summary of Contents for M2009 Series

Page 1: ...FAN RATING AC 120V 60Hz UL LISTED MODEL AC 552 READ AND SAVE THESE INSTRUCTIONS CEILING FAN OWNER S MANUAL MODELS M2009XX ...

Page 2: ...ight kit assembly j Glass shade k 7W LED bulb l Pull chains and fobs 2 m Package hardware 1 Mounting hardware screws 2 lock washers 2 star washers 2 wire nuts 3 wood screws 2 washers 2 2 Blade attachment hardware screws 16 fiber washers 16 3 Blade bracket hardware screws with lock washers 11 4 Balance Kit 1 Philips screw driver Blade screw driver 11 mm wrench Step ladder Wire cutters 1 TOOLS AND M...

Page 3: ...ge of the blades to the floor 7 Do not operate reversing switch while fan blades are in motion Fan must be turned off and blades stopped before reversing blade direction 8 Avoid placing objects in the path of the blades 9 To avoid personal injury or damage to the fan and other items be cautious when working around or cleaning the fan 10 Do not use water or detergents when cleaning the fan or fan b...

Page 4: ...eight of the fan at least 50 lbs Do not use plastic outlet boxes Figures 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling Fig 3 To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 Outlet box...

Page 5: ...e fan motor through the canopy and then through the ball downrod Step 6 Align the holes at the bottom of the downrod with the holes in the collar on top of the motor housing Fig 6 Carefully insert the hanger pin through the holes in the collar and downrod Be careful not to jam the pin against the wiring inside the downrod Insert the locking pin through the hole near the end of the hanger pin until...

Page 6: ... the blue wires are on the other side Step 5 Turn the connecting nuts upward and push the wiring into the outlet box Figures 9 and 10 illustrate the wiring connections for optional wall control The wire color out of wall control may vary see wall control s installation manual for correct wire connections WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR OTHER PERSONAL INJURY MOUNT FAN ONLY ON A...

Page 7: ...b in groove could cause damage to electrical wiring Figure 11 Figure 12 Outlet box Hanger bracket Canopy Screws 8 ATTACHING THE FAN BLADES CAUTION Remove 5 rubber packing mounts and discard before installation Step 1 Attach the blade to the blade bracket using the screws and fiber washers as shown in Figure 12 Start screw into bracket Repeat for the two remaining screws Step 2 Tighten each screw M...

Page 8: ...ting plate Mounting ring Screws 10 INSTALLATING THE LIGHT KIT TO THE SWITCH HOUSING 1 Remove and discard the center plug from the switch housing 2 Attach the light kit to the switch housing by feeding the light kit wires black and white through the hole of switch housing and then screw it onto the switch housing by nut lock washer Be sure it is tight enough to prevent light kit from vibrating loos...

Page 9: ...fore starting installation disconnect the power by turning off the circuit breaker or removing the fuse at fuse box Step 1 Remove the 3 screws from the mounting plate Step 2 While holding the Light kit assembly under your fan snap together the wire connection plug Fig 15 Step 3 Install the Light kit assembly onto the mountimg plate with 3 screws provided Be sure to tighten all screws Fig 15 Mounti...

Page 10: ...ight number of fans and so on The slide switch controls directions forward switch down or reverse switch up NOTE Wait for fan to stop before changing the setting of the slide switch Warm weather Forward A downward airflow creates a cooling effect as shown in Fig 17 This allows you to set your air conditioner on a warmer setting without affecting your comfort Cool weather Reverse An upward airflow ...

Page 11: ...g the finish The plating is sealed with a lacquer to minimize discoloration or tarnishing Do not use water when cleaning This could damage the motor or the wood or possibly cause an electrical shock 3 You can apply a light coat of furniture polish to the wood blades for additional protection and enhanced beauty Cover small scratches with a light application of shoe polish 4 There is no need to oil...

Page 12: ...ontrol s 7 Make sure the upper canopy is a short distance from the ceiling It should not touch the ceiling 1 Check that all blade and blade arm screws are secure 2 Most fan wobbling problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance Rotate the fan until the next blade is positioned for meas...

Reviews: