S
AV
i
O
Engineering, Inc. provides a manufacturer’s limited warranty of 1 year from original purchase date.
Warranty is non-transferable. Within the warranty period S
AV
i
O
will repair materials with manufacturing
deficiencies at their discretion. This warranty does not cover any faults caused by improper use, installation
and handling of the device or as a result of wear and tear. S
AV
i
O
Engineering, Inc. does not assume liability
for consequential damage caused by the failure of the S
AV
i
O
Water Master Pumps.
™
Warranty is void if the
product is not used in accordance with instructions. For warranty claims, please contact your dealership.
Warranty
Pump does
not run.
a) Connect power plug.
b) Disconnect the power cord, disassemble lower
housing and check if impeller is free to run.
a) Pump is not plugged in.
b) Impeller jammed.
Faults
Possible Causes
Remedies
The pump runs
but does not
deliver water.
a) Stop the pump and check water level.
b) Invert the pump to remove air bubble from
housing.
c) Disconnect the power, remove discharge tube
and clean.
d) Verify pump inlet is submerged in water.
a) Water level under the suction minimum.
b) Air bubble in the pump.
c) Discharge tube clogged or obstructed.
d) Pump is not priming.
Pump runs
intermittently.
a) Pump is too hot. Correct issue. Wait until the
pump has cooled and resume operation.
1) Check inlet and discharge for clogs and clean.
2) Water temp. should not exceed 95° F (35° C).
3) Fully submerge pump during operation.
a) Thermal protection engaged.
Possible issues:
1) Foreign object has jammed the
impeller or blocked the intake.
2) The pump was used in hot water.
3) The pump ran dry.
TYPE
WMS1450
WMS2050
WMS3600
Dimensions (h x w)
6” x 11 3⁄4”
6” x 12 1⁄2”
6” x 14”
Amps
1.6 - 2.3
2.3 - 3.0
4.7 - 6.0
Watts
180-250
240-350
500-650
Volts
115
115
115
Hertz
60
60
60
Max Flow
1450
2050
3600
Max Head
14’
16’
25’
Power Cord
16’ length
16’ length
16’ length
Troubleshooting
Precautions
Before perfoming any troubleshooting operation, disconnect
the pump from the power supply (by removing the plug from the socket).
S
AV
i
O
Engineering, Inc.
8 Water Garden Way
Santa Fe, NM 87508 USA
http://www.savio.cc • email: support
@
savio.cc
Specifications
4
Solids handling, current 2004.indd
6/18/2004, 3:14 PM
4