Pump does 

not run.

a) Connect power plug.
b) Disconnect the power cord, disassemble lower 
    housing and check if impeller is free to run.

a) Pump is not plugged in.
b) Impeller jammed.

Faults

Possible Causes

Remedies

The pump runs 
but does not 
deliver water.

a) Stop the pump and check water level.
b) Invert the pump to remove air bubble from 

     housing. 
c) Disconnect the power, remove discharge tube 
     and clean.
d) Verify pump inlet is submerged in water.

a) Water level under the suction minimum. 
b) Air bubble in the pump.

c) Discharge tube clogged or obstructed.

d) Pump is not priming.

Pump runs 

intermittently.

a) Pump is too hot. Correct issue. Wait until the 

    pump has cooled and resume operation.  

   1) Check inlet and discharge for clogs and clean.

 
   2) Water temp. should not exceed 95° F (35° C).        
   3) Fully submerge pump during operation.

a) Thermal protection engaged.
    Possible issues: 
     1) Foreign object has jammed the
      impeller or blocked the intake.
     2) The pump was used in hot water. 
     3) The pump ran dry.

TYPE

WMS1450

WMS2050

WMS3600

Dimensions (h x w)

6” x 11 3⁄4”

6” x 12 1⁄2”

6” x 14”

Amps

1.6 - 2.3

2.3 - 3.0

4.7 - 6.0

Watts

180-250

240-350

500-650

Volts

115

115

115

Hertz

60

60

60

Max Flow

1450

2050

3600

Max Head

14’

16’

25’

Power Cord

16’ length

16’ length

16’ length

Troubleshooting

Precautions 

Before perfoming any troubleshooting operation, disconnect 

the pump from the power supply (by removing the plug from the socket).

S

AV

i

O

 Engineering, Inc.

8 Water Garden Way

Santa Fe, NM 87508 USA

http://www.savio.cc • email: support

@

savio.cc

Specifications

4

Solids handling, current  2004.indd

6/18/2004, 3:14 PM

4

Reviews: