At the top of the waterfall, 

prepare the area for installation 

by excavating a 9” by 34” hole 

6” deep. Compact the soil in the 

bottom of the hole to prevent 

unwanted settling.

The FilterWeir includes two 

3” inlets (on either side of the 

housing). Select the unused 

side and apply glue to the ABS 

plug (provided). 

Before glue dries firmly press 

plug into unused FilterWeir 

inlet.

Connect the other inlet to your 

pump or Skimmerfilter using or 

flexible tubing.

Place FilterWeir into hole and 

level front to back and side 

to side. Tip the unit forward 

(toward the pond) slightly 

(about 1/4”) to compensate for 

settling.

Pull the pond liner up and over 

the front of the FilterWeir. Wipe 

the liner so that it is free of dirt 

and smooth wrinkles.

Summary of Contents for FilterWeir 31

Page 1: ...tions prior to assembling and operating Operating Manual Specifications F060 Great Equipment Is Just Part Of The Savio Excellence Line Savio manufactures a full assortment of products for healthy Livi...

Page 2: ...tion RC001 FilterWeir 31 Replacement Screw Pack RF022 FilterWeir 31 Housing RF023 FilterWeir 31 Media Grate RF024 FilterWeir 31 3 Inlet Plug RF025 FilterWeir 31 Replacement Filter Media Pad RF027 Filt...

Page 3: ...3 Components Diagram RC001 RF024 RS027 RF022 RF025 RF023...

Page 4: ...sed side and apply glue to the ABS plug provided Before glue dries firmly press plug into unused FilterWeir inlet Connect the other inlet to your pump or Skimmerfilter using or flexible tubing Place F...

Page 5: ...y hand Use a sharp utility knife to cut liner from inside spillway Remove liner from spillway Install media grate prior to backfilling Backfill around unit using pea gravel or soil that is free of clu...

Page 6: ...Know Marginal plants are those which grow around the margins of the pond where the water is shallow They usually have their soil and crown underwater and sometimes their lower foliage as well They are...

Page 7: ...November or when ice persistently develops on the pond Keep equipment winterized until late February or early March when the water temperature rises to 40 F or higher consistently If the pond is to b...

Page 8: ...r and tear Savio Engineering does not assume liability for consequential damage caused by the failure of the product Warranty is void if the product is not used in accordance with instructions For war...