12   YOUR GUARANTEE

 

In addition to the comprehensive 18 month warranty as set out below, and your statutory rights, 
Eco

1

  Limited  guarantee  that  you  will  save

 

at  least  the  Eco

recommended  selling  price  of  your 

Saveometer (any model) within one year of installation and permanent connection in the UK or 
you  may  return  it  to  us  (in  appropriate  protective  packaging,  fully  insured  &  prepaid  postage 
please).  If  you  return  any  unit  in  good  condition,  together  with  your  original  dated  receipt  or 
evidence of purchase and the relevant utility bills for the year in question, Eco

1

 will refund your 

purchase  price  in  full  providing  your  Saveometer  has  remained  permanently  connected.

 

Any 

returned  products  will  be  thoroughly  checked,  repackaged  and  provided  free  to  schools  for 
educational purposes. 

Register on line using 

www.saveometer.com/register

 or by completing and posting the enclosed 

guarantee card. To enjoy the Eco

1

 Limited unique guarantee your Saveometer must be registered 

within 14 days of purchase.  

18 MONTH WARRANTY 

The  Saveometer  PSM  is  guaranteed  against  manufacturing  defects  for  a  period  of  18  months.    This 
guarantee  does  not  cover  any  fault  caused  by  misuse  of  any  sort  including  contravention  of  the  user 
guide, or when any part of the product has been dropped or modified in any way. Please take care of your 
Saveometer PSM. 

 

Do not attempt to repair or service any part of the Saveometer Personal Smart Meter, in the 
event of any problems contact us at 

[email protected] 

 

Do not immerse in water, or any other liquids, or locate in a wet or damp environment 

 

Clean only with a soft duster or 

slightly

 damp cloth – do not use a spray of any sort  

 

Do not expose to heat, flames, water vapour, rain, snow  steamy conditions or extreme cold 

 

Do not hit strike or drop the equipment, or leave in direct sunlight  

 

If the display is accidentally broken take care not to touch the liquid crystals that may result. 

Eco

1

  Limited  will  replace  or  repair  any  defective  Saveometer  PSM  within  the  guarantee  period  free  of 

charge.    A  defective  Saveometer  PSM  must  be  returned  to  us,  at  your  own  expense  and  appropriately 
insured  and  packaged,  (where  possible  in  original  packaging)  together  with  copy  of  the  original  dated 
purchase  receipt.  Eco

1

  limited  will,  at  its  discretion,  repair  or  replace  defective  product.  *For  full 

guarantee details see www.saveometer.com, or request a printed copy by letter or by telephone. 

CHANGING THE TRANSMITTER BATTERIES 

The three rechargeable batteries are interchangeable between a transmitter and the 
display.To make sure you do not lose any data when the transmitter batteries require 
recharging we suggest that you exchange the batteries between the display and the 
transmitter, and then place the display on the charging base. 
 
 
 

 

No part or parts of the Saveometer should be disposed in household waste. This 
equipment should be taken to your local recycling centre for safe treatment.  
Details of your local recycling centre can be found at www.recycle-more.co.uk  or 
by telephoning your local council.

 

Summary of Contents for 2652

Page 1: ... you to save money and our environment every day for years to come Your new Saveometer PSM is designed to work out of the box We recognise that many people like to enjoy new purchases immediately and frequently start reading the user guide as a last resort But on this occasion please take time to read this guide and you will soon discover that the Saveometer has very many useful money saving featu...

Page 2: ...2 INDEX PAGE 1 Welcome 2 Index 3 What s in the box 4 Feature list 5 Getting Started 6 The Atomic clock 7 The Saveometer display 8 Accessing more information 9 How to change settings 10 Calculating your settings 11 Technical specification 12 Your guarantee 13 An abbreviated user guide 14 Typical sensor installations 15 A record of your chosen settings Saveometer display side view and support bracke...

Page 3: ...isplay 14 Battery low T transmitter 15 Pence or Cents 16 This area is used to display useful information This includes a 30 day dynamic bar chart or graph of your electricity use the most recent day enters from the right hand side prompts when varying settings messages 3 WHAT S IN THE BOX 2 Three sockets to connect sensor clip jacks are underneath Up to 3 jacks may be connected at a time Display c...

Page 4: ...aking it easy to see your cost trends at a glance Greenhouse gasses CO2 resulting from your electricity consumption may be displayed the Saveometer encourages thinking green as well as saving money Battery low indicators for transmitter T display D show when batteries are low Very low energy Eco friendly switching power supply The Saveometer PSM current sensor clip is efficient from half an amp up...

Page 5: ... batteries are installed the display will initially show a default date a 28 day simulated bar chart and NO DATA indicating that data is not being received from your electricity meter If the display fails to show anything please check the batteries are correctly installed and or recharge them immediately as described above before going any further 2 Set the time date To set the clock and date pres...

Page 6: ...vided The transmitter must be kept completely dry at all times 5 When the sensor clip has been correctly connected to the transmitter the display will stop showing NO DATA and show a default 28 day bar chart and also how much per hour you are currently spending on electricity If NO DATA continues to show check the sensor clip jack is properly inserted If NO DATA still continues to show it may be n...

Page 7: ...ndar from transmitters located worldwide These signals are always strongest at night and they enable clocks to achieve an accuracy of better than 1 second in 1000 years Thick brick or concrete walls basements and close proximity to other electronic apparatus especially power supplies may inhibit receiving atomic clock radio signals To optimise atomic clock radio signals it is best to extend the po...

Page 8: ...how after only a few days with the recent past day s cost trend always showing on the right hand side of the display The bar chart below shows a 30 day example of a user s rather erratic electricity consumption The battery low icons only appear when either the electricity transmitter batteries icon followed by T or the display batteries icon followed by D need recharging For the transmitter simply...

Page 9: ...his guide 3 Total Gas A gas transmitter will be required to be purchased This mode shows the total cost of gas since you last reset the Saveometer A symbol denoting gas is also shown 4 LAST WEEK The cost of electricity used in the previous week ending on Saturday at 12 00 pm 5 LAST MONTH Cost of electricity used in previous calendar month 6 LAST 1 4 Cost of electricity used in previous calendar qu...

Page 10: ...g a separate mode and to change any setting the procedure is identical How to change settings 1 Press the top button for 5 seconds until display shows TIME DATE release button and mode 01 will blink where the temperature is normally seen 2 Use the and keys to select the mode you require 3 Press S to select the mode 4 Use the and keys to vary the values as you wish 5 Press S to finish when the disp...

Page 11: ...ng the date the display will show SURE in the sequence to warn you the bar graph may be reset to an earlier date To accept press S in the normal way If reset to a later date the bar chart will reset to default and no other data will be lost When changing batteries seldom the time resets to nearest hour will reset automatically or can be manually re set Time date default settings vary according to ...

Page 12: ...E that you really do wish to proceed to zero the total cost by pressing S 000 00 7 Erase ALL acquired stored data This feature is seldom used and is primarily for when a Saveometer is reinstalled in a new location such as when moving home or business This enables you to erase all data that your Saveometer has ever acquired since it was first installed This mode will remove your bar chart all costs...

Page 13: ...Then select mode 14 and press S you will see the word register on the display Within 60 seconds press the green button on the transmitter until the red LED starts to blink release The red LED will soon stop blinking the new display will have been linked to the transmitter In about 10 seconds the display will show your current electricity cost per hour You may connect up to 25 displays to each tran...

Page 14: ...eplaced by the data received from the gas transmitter If no signal is received Gas Rx will continue to show To finish press S again to exit this mode You may find it useful to use a cordless or cellular phone to communicate when using this feature as the gas transmitter and a Saveometer display may be far apart n a Gas transmitters are sealed units and contain high quality long life lithium batter...

Page 15: ...tal 866 50 Total Kilowatt hours kWh charged were 27772 866 50 3 12p average cost per kilowatt hour 27772 If in doubt about the appropriate rate to set we suggest that you use a rate that is a little higher than your calculations in that way there will be no unpleasant surprises when your bill eventually arrives For more advice on setting your electricity and gas rates there is more useful informat...

Page 16: ...by 110uA Operation 25mA 1 mA average Battery Low indication Battery low indication at display for both the transmitter and display Battery Recharging Use only the transmitter display compatible charging base Remove connecting jack from transmitter before placing in charging base Power Supply Eco friendly very low power consumption Switching Mode SMPS Use only supplied power supply model S005CB0720...

Page 17: ...t Meter in the event of any problems contact us at customersupport saveometer com Do not immerse in water or any other liquids or locate in a wet or damp environment Clean only with a soft duster or slightly damp cloth do not use a spray of any sort Do not expose to heat flames water vapour rain snow steamy conditions or extreme cold Do not hit strike or drop the equipment or leave in direct sunli...

Page 18: ...it range Press 1 2 3 4 5 6 7 8 9 10 11 12 Each short press of the button will show the following Display shows Back light turns on if it is not already illuminated Total electricity cost since last reset Total gas cost since last reset Electricity cost last week Electricity cost last month Electricity cost last quarter Electricity cost last year kWh used current month kWh hours used this year Kilo...

Page 19: ...a Start time C rate n a Start time D rate n a 5 Cost alert LED s Off Less than 4p hr Green Over 4p hr Yellow Over 20p hr Red Over 30p hr Flashing Red Over 40p hr 6 Zero total electricity cost n a 7 Erase stored data n a 10 CO2 created 0 43 Kg kWh 14 Reset to default values n a 17 Set gas cost per kWh 3 4p kWh 18 Zero total gas cost n a 19 Set gas conversion factor s 0 32 CuFt to kWh 11 27 CuM to k...

Page 20: ...Failure to do so may damage the switch mode power supply Electricity sensor clip with three meter connecting wire and jack If the Saveometer is installed in a large house or in commercial premises it is likely that the electricity is a three phase supply A separate sensor clip is required for each phase Three sensor clips may be attached to a single transmitter NEW Gas sensor transmitter Your Save...