168
The steps of alarm reset through the additional function mode from the keypad is shown below.
[MENU]
[SET]
[SET]
[MENU]
End of resetting
8.3 Troubleshooting Method
(1) Overcurrent
【
Display
】
【
Description of detected alarm
】
The output current of the servo motor drive exceeds the rated value.
OC1: Direct detection by internal transistor of servo motor drive.
OC2: Indirect detection with software of servo motor drive.
【
Causes and Solutions
】
Causes
Solutions
Wrong servo motor output wiring
Correct the wiring of power cables (U, V and W).
Check cables visually or through continuity check and replace the
defective cable.
Short circuit or grounding fault in
Servo motor output wiring
Servo motor insulation fault
Measure the insulation resistance. (Several MΩ or over to ground)
Failure of servomotor
Measure the resistance across cables
. (Several Ω between cables)
Incorrect resistance of regenerative
resistor
Replace with the regenerative resistor within the rating.
Current imbalance caused by an
encoder fault
Replace the servo motor
Unconnected grounding cable
Connect the grounding cable