SL-1000 Owner’s Manual
Part No. 000729, 12-m11-2012
Maintenance
NOTE
The owner can perform the 3-month checks; 6-month checks
must
be
performed by a Qualified Technician. Contact your Authorized Dealer
.
Lockout Pin (public units only)
The lockout pin (on public units
only) is for use only by the
technician when performing
maintenance or for inspection
purposes. For normal use, the
lockout pin must be inserted
vertically into the storage hole.
This photo shows the pin in the
lockout position.
Lockout pin in
Insert lockout pin
in storage hole for
normal operation
lockout position
Verification by owner
Frequency
Check that the swivel seat switch is working.
Ensure the unit will not travel until the swivel seat is locked in
the riding position.
Every 3 months
Check that the footrest and carriage sensors are working.
Ensure the unit stops when it contacts an obstacle.
Every 3 months
Check that the emergency stop button is working.
Ensure the unit stops immediately when the button is
pressed.
Every 3 months
Verification by technician
Frequency
Check the operation of the limit switches.
Ensure the unit stops at the required position at the top and
bottom of the stairway.
Every 6 months
Check the operation of the overspeed brake.
Every 6 months
Lubricate the rollers using white lithium grease.
As required
Lubricate the seat swivel system using wheel bearing grease.
As required
Maintenance Schedule