background image

11

 

Gate

 

Locks

 

The

 

WR-500

 

gate

 

lock

 

keeps

 

the

 

gate

 

locked

 

when

 

the

 

platform

 

is

 

moving

 

and

 

not

 

at

 

a

 

landing.

 

NOTE

 

Keys are for

 

emergency

 

use only

 

and

 

should

 

always be kept

 

in

 

a

 

safe 

place for

 

use by

 

trained

 

personnel

 

only.

 

After

 

use of

 

any

 

emergency

 

function

 

(access key

 

or

 

manual

 

lowering

 

device),

 

ensure that

 

all

 

doors/gates are secure and

 

locked.

 

While the

 

emergency

 

function

 

is in

 

use,

 

DO

 

not

 

leave the area

 

unattended.

 

Emergency

 

Gate Opening

 

Figure 5

 

The

 

gate

 

can

 

be

 

opened

 

manually

 

using

 

the

 

emergency

 

key

 

provided

 

for

 

the

 

WR-500

 

lock

 

(Figure

 

5).

 

Insert

 

the

 

key

 

into

 

the

 

lock

 

and

 

turn

 

it

 

a

 

half

 

turn

 

clockwise

 

to

 

unlock

 

the

 

gate.

 

Pull

 

the

 

gate

 

open

 

and

 

then

 

turn

 

the

 

key

 

a

 

half

 

turn

 

counter-clockwise

 

to

 

remove

 

it

 

from

 

the

 

lock.

 

DO

 

NOT

 

open

 

the

 

gate

 

if

 

there

 

is

 

any

 

chance

 

of

 

falling

 

from

 

the

 

platform.

 

Safety

 

Brake

 

+EY0.

 

The

 

motor

 

Safety

 

Brake

 

stops

 

the

 

platform

 

in

 

the

 

 

 

event

 

of

 

a

 

chain

 

failure.

 

During

 

normal

 

operation,

 

the

 

chain

 

tension

 

keeps

 

the

 

brake

 

mechanism

 

up

 

so

 

the

 

brake

 

cam

 

does

 

not

 

interfere

 

with

 

the

 

tower

 

guide

 

rail.

 

If

 

a

 

chain

 

failure

 

occurs,

 

the

 

brake

 

mechanism

 

activates

 

and

 

stops

 

the

 

platform.

 

Emergency

 

Stop

 

Button

 

Pressing

 

the

 

red

 

Emergency

 

Stop

 

button

 

during

 

travel

 

will

 

stop

 

the

 

lift

 

immediately

 

and

 

activate

 

the

 

alarm.

 

The

 

Emergency

 

Stop

 

overrides

 

the

 

landing

 

(call/send)

 

stations.

 

Be

 

sure

 

to

 

pull

 

the

 

Emergency

 

Stop

 

button

 

out

 

to

 

return

 

the

 

lift

 

to

 

normal

 

operation.

 

Battery

 

Lowering

 

In

 

the

 

event

 

of

 

a

 

power

 

failure,

 

press

 

the

 

DOWN

 

button

 

to

 

bring

 

the

 

lift

 

to

 

the

 

lower

 

level.

 

Part

 

No.

 

001103,

 

10-m08-2021

 

M2LIFT

 

Owner’s

 

Manual

 

Summary of Contents for M2LIFT

Page 1: ...M2Lift Vertical Platform Lift Owner s Manual ...

Page 2: ...nce schedule Refer to this owner s manual for unit description setup operating instructions and a maintenance schedule for your Lift Upon completion of installation the Savaria mechanic must provide you with the information for the box below and ensure it is recorded in this owner s manual In addition either you or the Savaria mechanic must keep any service and or maintenance records in the Mainte...

Page 3: ...RIPTION 5 2 GENERAL SPECIFICATIONS 6 3 OPERATION 7 Attendant Operation 7 Operating from the COP Controls 7 Operating from the Landing Station Controls 8 4 ADDITIONAL FEATURES 10 Safety Underpan 10 Gate Lock 11 Safety Brake 11 Emergency Stop Button 11 Battery Lowering 11 5 MAINTENANCE 12 Maintenance Schedule 12 Operator Troubleshooting 14 Maintenance Record 15 Part No 001103 10 m08 2021 M2LIFT Owne...

Page 4: ...d personnelperform maintenanceand service on the unit When replacing parts be surethat only genuine Savaria parts are used This unit is intended for use by a mature person who understands its proper operation as set out in this manual WARNING At no time shouldchildren underthe age of 16 use the lift while unsupervised Prior to operation make sure that All doors and gates are locked and secure All ...

Page 5: ...LIFT Figure 1 Car operating Tower rail cap panel COP Landing gate COP side wall Tower Landing sill Opposite side wall Access ramp Fascia Non skid platform panel Motor cover Pit switch Safety underpan Base support legs Part No 001103 10 m08 2021 M2LIFT Owner s Manual ...

Page 6: ... phase Drive system Direct drive gear Chain suspension Motor 24 VDC 1 3 HP geared Controller LUT125 PCB Finish Electrostatic powder coat paint on all metallic surfaces and vacuumed formed plastics Standard features 24VDC operation Wireless call send stations at landings Constant pressure type buttons Operating control buttons on platform Automatic battery recharging system 115 VAC Low voltage cont...

Page 7: ...if the lift is unenclosed The attendant shall have full view of the floor area under the lift and of the rider at all times If the lift is enclosed the lift can be operated from the upper landing provided the operator has a view of the rider at all times During attendant operation the car directional controls must not be operational Operating from the COP Controls Figure 2 shows the car operating ...

Page 8: ... the unit is not in operation 5 Pressing the Emergency Stop button during travel will stop the lift immediately and activate the alarm The Emergency Stop overrides the landing station controls Pull the Emergency Stop out to return the lift to normal operation 6 If the gate is locked at a landing for more than 10 seconds you can press the Up button to unlock the gate Operating from the Landing Stat...

Page 9: ... open 3 When the lift reaches the landing the door will unlock automatically If you need to re open the door after the delay turn the key on and press the call Up button again to unlock the door 4 To prevent unauthorized useof the lift takethe key outwhen the unit is not in operation Part No 001103 10 m08 2021 M2LIFT Owner s Manual ...

Page 10: ... Figure 4 is located under the platform The underpan has sensors that detect any obstacles and stop the downward travel of the lift This is optional on enclosed units and required on open hoistways Figure 4 Safety Underpan M2LIFT Owner s Manual Part No 001103 10 m08 2021 ...

Page 11: ...ey a half turn counter clockwise to remove it from the lock DO NOT open the gate if there is any chance of falling from the platform Safety Brake EY 0 The motor Safety Brake stops the platform in the event of a chain failure During normal operation the chain tension keeps the brake mechanism up so the brake cam does not interfere with the tower guide rail If a chain failure occurs the brake mechan...

Page 12: ...ft is safely shored when working under the platform Maintenance Schedule Verification Frequency Verify general operation of the lift Every 2 months Verify correct operation of the underpan sensors Every 2 months Verify correct operation of the emergency stop Every 2 months Verify correct operation of the gate lock contacts The lift should not run unless the gate is closed and locked Every 2 months...

Page 13: ...stem The tensioners must be tight Every 6 months Verify that all hardware is tightened Every 6 months Check the safety brake Every 6 months Check the rollers function and wear Every 6 months Ensure that all filler panels are securely fastened in the gate Every 6 months Part No 001103 10 m08 2021 M2LIFT Owner s Manual ...

Page 14: ...he pan is not stuck in the activated position Platform comes down but does not go up Check that the power cord is plugged in Platform does not move Check that the key is ON Check that the gate is closed Check to see if the Emergency Stop buttons on the COP and tower are pushed in they must be pulled out for normal operation If the platform is at the top landing check the underpan sensors as descri...

Page 15: ...Maintenance Record Date Time Reason for call Comments Dealer ...

Page 16: ... service or questions about this product please contact your installing dealer Dealer Name Dealer Phone Authorized Savaria Dealer Savaria Concord Lifts Inc 2 Walker Drive Brampton ON L6T 5E1 Canada savaria com Part No 001103 2021 Savaria Corporation ...

Reviews: