Electrician Removal/Installation

 ELECTRIC SHOCK! 

The 120V AC, 60 Hz source power poses an electrical shock hazard that has the potential to cause serious 

injury to installers and end users.

 IMPORTANT NOTES!

 

A licensed electrician is required to install any of the Echo wireless lighting devices. Isolate and turn off power at the main 

breaker panel prior to installing any electrical devices.

 

For supply, neutral, and ground connections use only #14 AWG or larger solid copper wires (80°C) with insulation stripped 

to ⅝ in (16 mm).

1.  At the main breaker panel, switch the breaker that supplies power to the circuit to Off.
2.  Unscrew the wall plate and remove. Verify power is removed using a 120V AC tester.
3.  Unscrew the two 6-32 flat head screws and remove the existing toggle/rocker switch.
4.  Disconnect wires from the existing device and remove the device. It is good practice to label each wire as it is removed. If not  

already identified, mark wires to ensure proper rewiring. Especially if the circuit employs a 3-way configuration.

5.  Connect the in-wall wires to the leads coming from the Echo Auxiliary Control using the supplied wire nuts or approved 

alternative. Refer to either the Wiring Diagrams or Rear View Descriptions section. 

6.  Insert the Savant Auxiliary Control into the electrical switch box and secure with the 6-32 flat head screws provided. DO NOT 

use a powered screw driver. A powered screw driver can over tighten the screws.

7.  Re-establish power at the main breaker panel. 
8.  To test:

 

If the Auxiliary Control is wired to a Echo wireless switch, toggle the main button to the On (up) position and observe the 

load turns On. Toggle the main button to the Off (down) position and observe the load turns Off.

 

If the Auxiliary Control is wired into a Echo wireless dimmer/keypad, press and hold the main button in the On (up) position 

and observe the load increases in intensity. Press and hold the main button in the Off (down) position and observe that the 

load decreases in intensity. 

NOTE

: This test assumes a Savant Echo, Switch, or Keypad that the Auxiliary Control is connected to has previously been wired and 

tested. 

NOTE

: Install the wall adapter to cover the metal yoke prior to 

applying power. If replacing a Echo style device, remove 

power before removing the wall plate adapter

Multi-Gang Installations

When combining multiple keypads into a multi-ganged box, the outside tabs from one or both sides of each device so they all fit 

into the electrical switch box. Below are examples of 2, 3 and 4-gang scenarios.

 

Tabs are removed from both sides of the inside gang devices.

 

Tabs are NOT removed from outside edges of the devices at the end of each gang.

Wiring Diagrams

The diagrams below display how to wire the Echo Auxiliary Control as a companion to the Echo Dimmer/Switch. Both the basic 

wiring as well as the No Neutral diagrams are shown. Any unused wires must have the bare wire portion (stripped end) cut off and 

the wire must be capped with a wire nut. 

From 

Power

Example of two Auxiliary Controllers wired to Echo Dimmer/Switch

From

Power

Black 

Tape

Black

Tape

Example of one Auxiliary Control wired to Echo Dimmer (No Neutral)

WARNINGS

 

Using the Echo Dimmer or Keypad in a No Neutral configuration with loads other than incandescent is not supported.

 

The Echo Switch is not supported in a No Neutral 3-way configuration.

Wall Plate

Adapter

Wall Plate

Electrical

Switch Box

Mounting

Screws

Wall Plate and Adapter

sold separately