The Savant WIF-SWS104 (snow white) and WIF-LAS104 (light almond) wireless fan controllers incorporate a push button rotary dial 
that controls low, medium, and high speed on a 120V AC fan. In addition to the push button rotary dial, the front panel incorporates 
three LEDs which are a quick indicator of the current fan speed.
The fan controller can replace any existing standard 120V AC fan controller or switch that is wired into a standard 3-wire configuration 
(No Neutral not supported).
Finally, the Savant Fan Controller communicates with most 802.11 b/g/n wireless networks. Once communicating with the local LAN, the 
fan controller can be added to the Savant Control system to remotely control any fan through most iOS® or Android® devices.

 

IMPORTANT!

 Using this product in a manner that is not consistent with this document will void your warranty

Box Contents

Metropolitan Fan controller without faceplate

(2) Mounting Screws 6/32 x 

¾

 inch

(4) Wire Nuts

Quick Reference Guide (this document)

Optional Accessories

1 to 4-Gang Faceplates

Black conversion kits

Specifications

Environmental

Environmental

Temperature

32° to 104° F  (0° to 40° C)

Humidity

10% to 90% Relative Humidity (non-condensing)

Location

Indoor Use Only

Dimensions

Dimensions

Height

4.13 in (10.49 cm) / Shipping 7.0 in (17.78 cm)

Width

2.38 in (6.05 cm) / Shipping 4.5 in (11.43 cm)

Depth

1.81 in (4.60 cm) / Shipping 3.0 in (7.62 cm)

Weight (Shipping)

0.60 lb (0.272 kg)

Recommended Back Box Depth Dimensions

Recommended Back Box Depth Dimensions

All Metro fan controllers require a standard U.S. electrical back box  
• Recommended - 3.5 in (8.89 cm) deep
• Minimum - 2.25 in (5.72 cm) deep

All Metro fan controllers require a standard U.S. electrical back box  
• Recommended - 3.5 in (8.89 cm) deep
• Minimum - 2.25 in (5.72 cm) deep

Power

Power

Input

120V AC at 60Hz

Load Power (Max)

180W 1.5A @ 120V AC

Supported Load Types

Supported Load Types

Fan (

120V AC )

Fan (

120V AC )

Standards

Standards

Wireless

802.11 b/g/n

Security

WPA1™, WPA2™, WPA1™+WPA2™, WEP

Regulatory

Regulatory

Safety and Emissions

FCC Part 15  |  UL 
For more details, refer to the 

Regulatory

 section

Contains FCC ID:

TLZ-CU277

Contains IC:

6100A-CU277

RoHS

Compliant

Minimum Supported Release

Minimum Supported Release

Savant® OS

da Vinci® 7.2.1

Front View

A

Ambient Light Sensor

 - Senses the level of ambient light in the room and adjusts the LED brightness on the front panel. 

The ambient light sensor operation can be modified in Blueprint. 

B

Reset Button

 - The reset button has two functions:

• Press and release the reset button. After button is released, all LEDs on the front panel illuminate for two seconds and 

then flash twice. Pressing the reset button causes the fan controller to calibrate itself to the circuit it is being installed 
to. After the fan controller calibrates itself, it then reboots. After the reboot, the LED sequencing is determined by 
whether the device had previously been connected to a network. Refer t

LED Sequencing

 table.

Note:

 The reset button should always be pressed after the Metropolitan device is installed.

• Press and hold the reset button for five seconds until all LEDs on the front panel illuminate. The LEDs will remain on 

for two seconds and then flash twice. The fan controller then reboots and reverts to Provisioning Mode. In 
Provisioning Mode, the first two LEDs on the front panel blink in an alternating pattern waiting to be provisioned. 
Refer to the 

LED Sequencing

 table.

C

Rotary Dial/Button

 - 

Press the rotary button/dial to switch the load (fan) On and O

. Once switched On, turning the 

dial counterclockwise decreases the speed of the fan. Turning the dial clockwise increases the speed of the fan. The 
three LEDs above the dial indicate speed of the fan. As the speed of the fan increase, more LEDs are lit. As the speed of 
the fan decreases, less LEDs are lit. When configured in Blueprint, the LEDs track the scene configured.

D

Service Switch

 - The service switch removes power from the load (red wire). Toggle the service switch to O

 whenever 

changing the load. The service switch can also be used to power cycle the fan controller.

Rear View

Device wires are all a five inch #16 AWG stranded wire.

Green

Ground

 - Wire to Gnd.

White

Neutral

 - Return path for voltage.

Red

Load

 - Wire to the load.

D

Black

Line

 - Wire to hot wire from AC power source.

Metropolitan Wireless Fan Controller  |  009-1340-02  |  150604

45 Perseverance Way, Hyannis, MA 02601

Copyright © 2015 Savant Systems, LLC

1

of

2

Savant.com

 |  508.683.2500

Metropolitan Wireless Fan Controller WIF-xxx104