1.  At the main breaker panel, switch off the breaker that supplies power to the keypad that is being replaced. On existing Savant low 

voltage systems, remove power from the breaker that supplies power to the SKL-3040 or SKL-1010 keypad controller.

2.  When replacing an existing keypad, refer to the keypad’s owner’s manual for proper removal techniques.

3.  Disconnect and label each wire as they are detached from the in-wall wires. Labeling ensures the wires get installed onto the new 

keypad correctly.

4.  Screw the Ascend style keypad wall plate adapter to the electrical box using the two #6-32 x 

3/4

 inch screws supplied with the new 

keypad. Tighten the screws so the adapter sits flush on the wall. DO NOT use a powered screwdriver. A powered screwdriver can 

over-tighten and possibly warp the adapter.

5.  Connect the in-wall wires to the supplied 5-inch keypad pigtail using an approved wire nut or a similar alternative. Refer to the 

Rear 

Panel

 section above when making the connections.

Removal and Installation

6.  Plug the pigtail wire into the rear of the keypad. The connector 

is keyed and can only be plugged one way.

7.  Slide the keypad over the wall plate adapter and ensure the 

keypad snaps into the four slots located at each corner of 

the adapter. Press on all four corners to ensure the keypad is 

secure and sitting flush on the wall. 

8.  Switch on the breaker that supplies voltage to the new keypad. 

The keypad will go through a boot sequence, and the button 

backlights will cycle red, green, blue, then white. 

9.  When the boot sequence completes, the backlights then blink 

red to indicate the keypad is in the discovery process and the 

keypad controller is looking for any keypads wired to each 

keypad bus. Refer to the 

Button Backlight Sequencing

 section 

below for information on the various states.

Wall Plate

Mounting 

Screws

Electrical Box

Keypad

10. Once discovered, the keypads enter the next state and are ready to be programmed using Blueprint’s lighting and shade manager. 

Programming information is available in the 

Low Voltage Deployment and Programming Guide

. This guide and more can be located 

in the 

Lighting Documentation Portal

 available on the 

Savant Community

.

Whether installing a new keypad or replacing an existing one, refer to the instructions below.

 

IMPORTANT NOTES:

 

When working with electricity, even low voltage electricity, follow all standard electrical and safety precautions to avoid leaving 

exposed or bare wires that can short and cause damage to the equipment or yourself.

 

Savant recommends a licensed electrician be used to make the electrical connections.