Savant SIS-5000S-00 Quick Reference Manual Download Page 1

The Savant® Intercom Server enables 3rd Party Intercom Door/Gate 
entry products and intercom enabled iOS devices to create a 
Savant® Intercom Server Solution that integrates easily into an 
existing Savant Control System. Once installed and configured, the 
Savant Intercom can communicate with various 3rd Party Intercom 
Door/Gate entry systems to supply audio and/or video of the 
entrance to your facility or home.
This Quick Reference Guide gives basic information about the 
Savant Intercom along with initial installation and wiring procedures. 
Once installed and connected, refer to the 

Savant SIS-5000S-xx 

Intercom Deployment Guide

 for configuration and integration 

procedures. 

Box Contents

(1) Savant Intercom Server (SIS-5000S-00)
(1) Power cord
(1) Quick Reference Guide (this document)

Supported Devices

1U Rack System (RCK-3000-xx)

3rd Party Door Entry systems

Holovision Analog Intercom Door/Gate Entry

Holovision VoIP Intercom Door/Gate Entry

Siedle Analog Intercom Door/Gate Entry

Mobotix VoIP Intercom Door/Gate Entry

Savant TrueControl™ II for iOS

TEL-IAD2-xx Integrated Access Device (Analog to VoIP 
conversion)

PAS-1000-xx Public Announcement System 

Specifications

Environmental

Environmental

Temperature

Operating

: 50° to 95° F  (10° to 35° C)

Temperature

Storage

: -40° to 116° F  (-40° to 47° C)

Humidity

5% to 95% RH (non condensing)

Cooling

15 cubic feet per minute (CFM) recommended

Noise

12dBA at idle

Dimensions and Weight

Dimensions and Weight

Height

1.4 in (3.6 cm)

Width

7.7 in (19.7 cm)

Depth

7.7 in (19.7 cm)

Weight

2.6 lb (1.20 kg)

Rack Space

1U

Power

Power

Input Power

100-240V AC 50/60Hz

Maximum Power  85W 

Memory

Memory

Memory

8 GB 

Compliance

Compliance

Safety and 
Emissions

FCC Part 15 | CE Mark  | C-Tick

RoHS

Compliant

Minimum Supported Release

Minimum Supported Release

Savant OS

da Vinci 7.0.2

Front Panel

Power LED

Illuminates white when host is powered On.

Rear Panel

Power Button

Power On:

 Press while powered O

Power Button

Power O

1. Launch a Terminal window from the SDE.
2. SSH into the SIS-5000S:

ssh   RPM@<ip_of_   SIS5000S>

3. Enter default password: 

RPM.

4.At the prompt, enter shutdown command:

sudo   shutdown   -­‐P   now   

5. When prompted, enter the default password 

again: 

RPM.

6. Verify the SIS-5000S

 Power 

LED is o

.

7. Unplug the SIS-5000S.

Power Input

100-240V AC

 

50/60Hz

Ethernet

10/100/1000 Gigabit Ethernet Port. Connect 
to a managed Ethernet switch within your 
local network. 

Cooling Vents

Output for cooling of the internal processor. 
DO NOT BLOCK

Note:

 Connections not identified in the diagram above are not 

functional within a Savant Configuration/Installation.

Power Management Recommendations

Savant recommends a pure sine wave uninterruptible power supply 
(UPS) with the ability to shut down the SIS-5000S before the 
battery runs out of power.  

Never remove power from the 

SIS-5000S before shutting it down

.

Additional Documentation

Refer to the following documents located on the 

Savant Customer 

Community

 for for additional information.

Savant intercom Server (SIS-5000S) Deployment Guide

SIS-5000S-00  |  009-1302-01  |  150626

SIS-5000S-00  |  009-1302-01  |  150626

45 Perseverance Way, Hyannis, MA 02601

Copyright © 2015 Savant Systems, LLC

1 of 2

savant.com

  |  508.683.2500

Savant® Intercom Server
Quick Reference Guide

For Product Info

Reviews: