SHR-2000 Quick Reference Guide | 009-1909-03
45 Perseverance Way, Hyannis, MA 02601
Copyright © 2021 Savant Systems, Inc. | 210611
1 of 2
Front Panel
Power
Status
A
B
C
A
Power LED
Green
: System has power and is operating
normally.
Off
: System is not receiving power.
B
Status LED
Off
: Disconnected from power supply.
Amber
: Host is booting/rebooting and is
disconnected from the network.
Green
: Connected to the local network and is
assigned an IP Address.
C
Mounting
Points
Threaded insert for use with optional rack
mounts
Box Contents
(1) Savant® Smart Host Rack Mountable - (SHR-2000)
(1) Install Kit (075-0223-xx)
(1) Multi-Blade
5V DC 3A Power Supply (025-0223-xx)
(2) 6-pin Screw Down Plug-in Connector (028-9352-xx)
(2) 3-pin Screw Down Plug-in Connector (028-9351-xx)
(1) Product and Regulatory Insert (009-1950-xx)
Specifications
Environmental
Temperature
32° to 104° F (0° to 40° C)
Humidity
10% to 90% Relative Humidity (non-condensing)
Cooling
10 CFM
Maximum BTU
34.1 BTU/hr
Dimensions and Weights
Height
Width
Depth
Weight
Device
1.6 in
(4.15 cm)
8.5 in
(21.50 cm)
3.7 in
(9.33 cm)
1.4 lbs
(0.64 kg)
Shipping
2.2 in
(5.59 cm)
12 in
(30.48 cm)
7.3 in
(18.54 cm)
2.3 lbs
(1.05 kg)
Rack Space
1U
Power
Input Power
5V DC 3A
Maximum Power
15
watt
s
Power over
Ethernet (PoE)
IEEE 802.3af
Regulatory
Safety and
Emissions
FCC Part 15
CE
C-Tick
UKCA
RoHS
Compliant
Minimum Supported Release
Savant OS
da Vinci 9.2
Chassis Installation
The Smart Host can be installed on a solid, flat, level surface such as a
table, cabinet, or shelf. The location should be dry, well ventilated, and
out of direct sunlight.
Rack
The optional RMB-PAVAM2F-xx or RMB-PAVAM2-xx allows two
devices to be mounted side by side. For example, a Smart Host can
be mounted next to a PAV-AIM7C. This rack is compatible with all
standard 19-inch National Electrical Manufacturers Association (NEMA)
rack mounts.
The instructions below show the RMB-PAVAM2F-xx, both brackets
install the same way they just face different directions.
1. Align the bracket with the Smart Host mounting points.
2. Attach using the screws provided with the bracket.
Network Configuration
For information on network requirements, refer to the
Savant Device
Networking Guidelines
.
Refreshing the IP Connection
After connecting to a new network, changing routers, or if the IP
Address range in the router was changed, the IP connection should be
refreshed. To refresh the IP connection, do one of the following:
–
Hot Plug the Ethernet (LAN) Connection
–
Cycle power
Savant® Smart Host Rack Mountable (SHR-2000)
Quick Reference Guide