Rear Panel

A

Reset (hole)

To clear the Wi-Fi or wired Ethernet settings, 

press and hold the reset button for five seconds 

until the LED blinks red rapidly; then release. 

 

HELPFUL!

 This resets the network settings 

to their factory defaults. Static IP Ad-

dresses or Wi-Fi settings will be lost.

B

Power Input

5V DC 3A - Connect to included power supply.

C

Status LED

 Off

-Disconnected from power supply.

 Amber

 - Controller is booting/rebooting and 

is disconnected from the network.

1s

1s

1s

Repeat

1s

 Amber Flashing 

 - Host is not 

connected to a wired Ethernet network and has 

not joined a Wi-Fi network.

 Green

 - Connected to either a wired Ether-

net network or a Wi-Fi network.

D

Digital Au-

dio Output

TOSLink (Optical) digital audio output. Connect 

to digital optical audio input on switcher for 

using the Audio Interrupt Service (AIS).

E

Ethernet

8-pin RJ-45 female.
10/100/1000 Base-T auto negotiating port. Con-

necting to this port will disable Wi-Fi settings.

F

RS-232

8-pin RJ-45 female.
Used to transmit and receive serial binary data 

to and from serial controllable devices.
Ports 1-2 RS-232 - CTS/RTS handshaking. CTS 

RTS handshaking availability is based on the 

component profile.
See 

RS-232 Wiring

 section for pin-outs.

G

IR

6-pin Screw Down Plug-in Connector. Used to 

send IR signals to control devices with an IR 

input or IR receiver via an IR flasher (5V toler-

ant only). See 

IR Wiring

 section for important 

precautions regarding IR functionality before 

making connections.

H

Relay

3-pin Screw Down Plug-in Connector. See 

Relay 

Wiring

 section for pin-outs. 

Normally Open (NO) / Normally Closed (NC) to 

control devices requiring basic on/off operation. 

DC Voltage Max: 30V DC 1A

I

GPIO

3-pin Screw Down Plug-in Connector. See 

GPIO 

Wiring

 section for pin-outs. 

GPIO Input

 - When configured as an input, the 

processor will look for a low (<0.8V DC) or a 

high (>2.4V DC) state.
Minimum 0V DC / Maximum 12V DC.

GPIO Output

 - When configured as an output, 

the port provides a binary output of 0-12V DC 

150mA max.

(1)  Savant® Smart Host with Control (SHC-2000-05)
(1)  5V DC 3A Power Supply 
 

with (4) Quick Change AC Adapters (025-xxxx-xx)

(2)  M3x6 mm Flathead Phillips Screw Black (039-0001-xx)

Wall Bracket:
(1)  Wall Mount Frame (074-0585-xx)
(1)  Host Mount (074-0584-xx)
(2)  6-pin Screw Down Plug-in Connector Black (028-0664-xx)
(2)  3-pin Screw Down Plug-in Connector Black (028-0665-xx)
(1)  Quick Reference Guide (this document)

Box Contents

Specifications

Environmental

Temperature

32° to 104° F (0° to 40° C)

Humidity

10% to 90% Relative Humidity (non-condensing)

Cooling

10 CFM

Maximum BTU

51.5 BTU/hr

Power

Input Power

5V DC 3A

Maximum Power

15 watts

Minimum Supported Release

Savant OS

da Vinci 8.6

Regulatory

Safety and 
Emissions

FCC Part 15

CE

C-Tick

ICES-003

RoHS

Compliant

Standards

Wireless

Wi-Fi (802.11 b/g/n dual band 2.4 and 5.0 GHz)

 

IMPORTANT!

 802.11r fast roaming is not 

supported

Dimensions and Weights

Height

1.58 in (4.0 cm)

Width

7.86 in (19.9 cm)

Depth

7.65 in (19.4 cm)

Weight

Net: 1.3 lb (.58 kg)

Shipping 2.1 lb (.95 kg)

Rack Space

1U

NO

NC C

/ /

G 1 PD

Ethernet

RS232-1

RS232-2

-

- 4 +

+

5

-

+

6

- 1

3

-

+

+

2

-

+

Audio

Status

5VDC

Reset

C

A B

D

E

G

H

F

I

Refreshing the IP Connection

Network Configuration

 

– Hot Plug the Ethernet (LAN) Connection

 

– Cycle power

After connecting to a new network, changing routers, or if the IP 

Address range in the router was changed, the IP connection should be 

refreshed. To refresh the IP connection, do one of the following:

To ensure the IP Address will not change due to a power outage, a 

static IP Address or DHCP reservation should be configured. Savant 

recommends using DHCP reservation within the router. By using this 

method, static IP Addresses for all devices can be managed from a 

single UI, avoiding the need to access devices individually.

Setting DHCP reservation varies from router to router. Refer to the 

documentation for the router to configure DHCP reservation.

For Product Info

Savant® Smart Host with Control 

Quick Reference Guide

Reviews: