SHC-2000-05 | 009-1616-01 | 180207
Copyright 2018 Savant Systems, LLC
45 Perseverance Way, Hyannis, MA 02601
| 508.683.2500
1 of 2
Rear Panel
A
Reset (hole)
To clear the Wi-Fi or wired Ethernet settings,
press and hold the reset button for five seconds
until the LED blinks red rapidly; then release.
HELPFUL!
This resets the network settings
to their factory defaults. Static IP Ad-
dresses or Wi-Fi settings will be lost.
B
Power Input
5V DC 3A - Connect to included power supply.
C
Status LED
Off
-Disconnected from power supply.
Amber
- Controller is booting/rebooting and
is disconnected from the network.
1s
1s
1s
Repeat
1s
Amber Flashing
- Host is not
connected to a wired Ethernet network and has
not joined a Wi-Fi network.
Green
- Connected to either a wired Ether-
net network or a Wi-Fi network.
D
Digital Au-
dio Output
TOSLink (Optical) digital audio output. Connect
to digital optical audio input on switcher for
using the Audio Interrupt Service (AIS).
E
Ethernet
8-pin RJ-45 female.
10/100/1000 Base-T auto negotiating port. Con-
necting to this port will disable Wi-Fi settings.
F
RS-232
8-pin RJ-45 female.
Used to transmit and receive serial binary data
to and from serial controllable devices.
Ports 1-2 RS-232 - CTS/RTS handshaking. CTS
RTS handshaking availability is based on the
component profile.
See
section for pin-outs.
G
IR
6-pin Screw Down Plug-in Connector. Used to
send IR signals to control devices with an IR
input or IR receiver via an IR flasher (5V toler-
ant only). See
section for important
precautions regarding IR functionality before
making connections.
H
Relay
3-pin Screw Down Plug-in Connector. See
section for pin-outs.
Normally Open (NO) / Normally Closed (NC) to
control devices requiring basic on/off operation.
DC Voltage Max: 30V DC 1A
I
GPIO
3-pin Screw Down Plug-in Connector. See
section for pin-outs.
GPIO Input
- When configured as an input, the
processor will look for a low (<0.8V DC) or a
high (>2.4V DC) state.
Minimum 0V DC / Maximum 12V DC.
GPIO Output
- When configured as an output,
the port provides a binary output of 0-12V DC
150mA max.
(1) Savant® Smart Host with Control (SHC-2000-05)
(1) 5V DC 3A Power Supply
with (4) Quick Change AC Adapters (025-xxxx-xx)
(2) M3x6 mm Flathead Phillips Screw Black (039-0001-xx)
Wall Bracket:
(1) Wall Mount Frame (074-0585-xx)
(1) Host Mount (074-0584-xx)
(2) 6-pin Screw Down Plug-in Connector Black (028-0664-xx)
(2) 3-pin Screw Down Plug-in Connector Black (028-0665-xx)
(1) Quick Reference Guide (this document)
Box Contents
Specifications
Environmental
Temperature
32° to 104° F (0° to 40° C)
Humidity
10% to 90% Relative Humidity (non-condensing)
Cooling
10 CFM
Maximum BTU
51.5 BTU/hr
Power
Input Power
5V DC 3A
Maximum Power
15 watts
Minimum Supported Release
Savant OS
da Vinci 8.6
Regulatory
Safety and
Emissions
FCC Part 15
CE
C-Tick
ICES-003
RoHS
Compliant
Standards
Wireless
Wi-Fi (802.11 b/g/n dual band 2.4 and 5.0 GHz)
IMPORTANT!
802.11r fast roaming is not
supported
Dimensions and Weights
Height
1.58 in (4.0 cm)
Width
7.86 in (19.9 cm)
Depth
7.65 in (19.4 cm)
Weight
Net: 1.3 lb (.58 kg)
Shipping 2.1 lb (.95 kg)
Rack Space
1U
NO
NC C
/ /
G 1 PD
Ethernet
RS232-1
RS232-2
-
- 4 +
+
5
-
+
6
- 1
3
-
+
+
2
-
+
Audio
Status
5VDC
Reset
C
A B
D
E
G
H
F
I
Refreshing the IP Connection
Network Configuration
– Hot Plug the Ethernet (LAN) Connection
– Cycle power
After connecting to a new network, changing routers, or if the IP
Address range in the router was changed, the IP connection should be
refreshed. To refresh the IP connection, do one of the following:
To ensure the IP Address will not change due to a power outage, a
static IP Address or DHCP reservation should be configured. Savant
recommends using DHCP reservation within the router. By using this
method, static IP Addresses for all devices can be managed from a
single UI, avoiding the need to access devices individually.
Setting DHCP reservation varies from router to router. Refer to the
documentation for the router to configure DHCP reservation.
For Product Info
Savant® Smart Host with Control
Quick Reference Guide