Savant CLI-1WIRE2 Quick Reference Manual Download Page 2

CLI-1WIRE2-00  |  009-1829-00  |  190613 

Copyright 2019 Savant Systems, LLC

45 Perseverance Way, Hyannis, MA 02601 

Savant.com

  |  508.683.2500

2     of     2

When making connections, follow the guidelines set below to ensure a 

safe and secure connection.

Use the diagram below when wiring the 1-Wire smart sensors. 

Making Connections

Power Connections

RS-485 Connections

1-Wire Smart Sensor Connections

Refer to the following documents located on the 

Savant Customer 

Community

 for additional information.

 

– Multistat Smart Thermostat Deployment Guide (009-1636)

 

– Multistat Thermostat with Touchscreen (009-1593)

Additional Information

1.  With a small slotted screwdriver, turn 

the screws on the connector coun-

terclockwise (CCW) until the silver 

crimps open enough to slide a wire 

into the square slots.

2.  Strip back insulation on each wire to 

1

/4

 

inch and insert the stripped wire 

into the proper connection.

3.  Turn the screw clockwise (CW) until 

the crimps tighten around each wire. 

Tug on each wire a bit to verify they 

are secure.

< 1/8 inch of

bare wire

exposed

Use the diagrams below when making the power connections be-

tween the thermostat and CLI-1WIRE2 climate module.

o

G

AUX 
OUT

AUX 
IN

RS2

RS1 GND

GND

R

X-

RX+

GND

1-

WIRE

5V 
DC

Y2

Y1

W2

W1

RC

RH

TX+ TX- 24C

1-Wire

Status

CLI-1WIRE2-00

S/N:

UID:

SHR184671332

001AAE09CA340065

1

2

+5V

1Wire

Gnd
+5V

1Wire

Gnd

24VAC

~

~

Power can be 

daisy-chained

to other modules

24V AC 

from HVAC

 

– Power can be daisy-chained between modules.

 

– The cable lengths vary depending on the size of the wire. See the 

specifications table on page 1 for more information.

 

– Up to two sensors can be wired per input port with a cumulative 

length of 600 feet (182 meters)

 

– Savant recommends using Cat 5e/6/7 when making connections.

 

– The table below shows the recommended connections when using 

a Cat 5e/6/7 cable.

o

G

AUX 
OUT

AUX IN

RS2

RS1 GND

GND

GND

R

X-

RX+

GND

1-

WIRE

5V 
DC

Y2

Y1

W2

W1

RC

RH

TX+

(TX+)

TX-

(TX-)

24C

Left Side View

RS-485 Cable

CLI-1WIRE2

Use the diagrams below when making the RS-485 connections be-

tween the thermostat and CLI-1WIRE2 climate module.

 

– Max cable length is 1000 feet (304.8 meters).

 

– Savant recommends using standard RS-485 cable for wire runs.

1-Wire

Status

CLI-THLFM1

Splice up to two 

sensors per input

Use Cat 5e/6/7

CLI-THLFM1

CLI-1WIRE2-00

S/N:

UID:

SHR184671332

001AAE09CA340065

1

2

+5V

1Wire

Gnd
+5V

1Wire

Gnd

24VAC

~

~

CLI-THFM1

Cat 5e/6/7 cable

Description

Black

White/Blue Stripe

Gnd

Blue

Blue

Data

Red

Orange

+5V DC