background image

The Savant Multi-Room AMP (AMP-8125) Quick Reference Guide provides all the steps 

necessary to set up the AMP-8125.

Box Contents

(1) AMP-8125

(1) Installation Kit (075-0142-xx)

(2) 1U Rack Mounting Brackets  (071-0715-xx)

(4) Screws for Rack Mounts (039-0236-xx)

(6) Torx Screws for Brackets (039-0237-xx)

(1) Torx  Wrench (071-0755-xx)

(4) Plastic Feet (074-0445-xx)

(4) Phillips Screws for Plastic Feet (039-0238-xx)

(4) 4-position Phoenix-style Connectors for audio output (028-0454-xx)

(1) 3-position Phoenix-style Connector for Trigger I/O (028-0455-xx)

(1) Power cord (3 feet) (N. America) (064-0333-xx) or appropriate international power cord

(1) Quick Reference Guide (this document)

Required System Component

(1) Any Savant Controller with RCA Audio Output connectors

Specifications

Environmental

Environmental

Temperature

32° to 95° F  (0° to 35° C)

Humidity

10% to 80% Relative Humidity (non-condensing)

Cooling

34 cubic feet per minute (CFM) recommended.

BTUs

650 BTUs per hour

Dimensions and Weight

Dimensions and Weight

Height

1.70 in/4.50 cm

Width

17.30 in/43.94 cm

Depth

14.9 in/37.88 cm

Weight

9.2 lb/4.2 kg

Rack Space

1U

Power

Power

Input Power 

100-240V AC, 50/60 Hz 

Nominal Power

190 watts

Operating Parameters

Operating Parameters

Output Power

125W RMS/channel@8 ohms from 20Hz - 20kHz (all 

channels driven)

Frequency Response

20Hz - 20kHz +0dB/-1.5dB

Total Harmonic Distortion (THD) <0.05% - 20Hz - 20KHz (At Full Rated Power)
Signal-to-Noise Ratio (SNR)

>105dB ref: full power (a-weighted)

Crosstalk

< -70dB @ 1kHz

Input Sensitivity

1.12 volts for 125 watts out in 8 ohms

Gain

29dB

Input Impedance

100K ohms (typical)

Compliance

Compliance

Safety and Emissions

FCC Part 15  |  CE  |  CAN/CSA  |  C-Tick

RoHS

Compliant

1

2

1

Standby Button

Red 

indicates that the unit is in standby mode.

Blue

 indicates that the system is powered on.

2

Channel Status LEDs

(1-8)

Blue

 indicates the channel has adequate power and is 

operating normally.

Blue flashing

 indicates the channel has a fault such as a short 

or some other problem.

Off 

indicates that the system is in standby mode.

1

2

3

4

5

6

7

8 9

10 11

12

1

Bus Output

Provides RCA connector loop/pass-thru output for connecting 

multiple AMP-8125s in a system utilizing a single bus input 

signal.

2

Bus Input

Provides RCA connectors input to simultaneously feed all 

speaker output channels utilizing a single bus input signal.

3

Local Inputs

Provides eight RCA input connectors input to feed a 

corresponding speaker-level output channels labeled in pairs 

A, B, C and D. . 

4

Output Level Controls

Provides eight Stereo line-level audio outputs labeled in pairs 

A, B, C and D. 

5

Stereo Mono 

Selection

Selects between stereo and mono output configuration for 

each group of speaker output pairs.

6

Local/Bus Selection

Selects between local and bus inputs for each group of 

speaker output pairs.

7

Speaker Outputs

Provides connection for up to four pair of stereo speakers.

8

Signal Sense On/Off

Enables the audio Signal Sense circuitry for the bus and local 

inputs.

9

Power Save On/Off

Enables the extreme low-power automatic standby mode.

10

Trigger In/Out  

connector 

(Phoenix-style)

Provides connectivity for remote 5-15V DC trigger signals 

used to activate and deactivate the standby mode from 

devices.

11

Trigger In/Out

connector

(Mono mini- plug)

Provides connectivity for remote 5-15V DC trigger signals 

used to activate and deactivate the standby mode from 

devices.

12

Input Power

100-240V AC, 50/60 Hz

 

Note:

 The Power Save function can only be used when operating the AMP-8125 from the front 

panel standby button. If a trigger input is being used, it will override the Power Save function.

Installation Considerations

The AMP-8125 should be installed on a solid, flat, level surface such as a table or shelf using the  

four plastic feet that are shipped with the product.The AMP-8125 can also be installed in a 

standard 19-inch equipment rack using the rack-mount brackets included with the product. 

Select a dry, well ventilated location out of direct sunlight. 

If multiple AMP-8125s are rack mounted together, it is acceptable to “flat stack” them one atop 

the other in adjacent rack spaces without additional ventilation spaces left in between them. 

However, in some installations or in heavy usage scenarios where multiple channels are 

consistently driven at high outputs for long periods of time, it might be necessary to leave one 

empty rack between the amplifiers in order to assist with heat dissipation and prevent thermal 

protection due to overheating.

Cable and Wire

The AMP-8125 has multiple connections on the back panel. Savant recommends that the input 

cables and the speaker wires are clearly labeled. Label the cables and the wires with their 

destination or source, not the AMP-8125 terminal. Modifications will be easier in the future.

The AMP-8125  connects to your  Savant  multi-room  audio  solution via shielded  line level  audio 

cables  with  RCA Audio  Output  connectors.  Use  high  quality  RCA  cables to  connect  the  multi-

room audio to the amplifier inputs. 

The AMP-8125 connects to your speakers using 2-conductor speaker wire. For most 

applications, Savant recommends using 16 or 18 gauge wire. For wiring runs longer than 80 feet 

Savant recommends using 14-gauge wire. Each channel features a removable screw terminal 

speaker connection for easy installation in tight spaces. The terminal connector can 

accommodate up to 14-gauge stranded speaker wire.

Savant Multi-Room AMP

(AMP-8125)

Quick Reference Guide

009-0631-02

AMP-8125-00

Copyright © 2012 Savant Systems, LLC. SAVANT and RacePoint Blueprint are trademarks of Savant Systems, LLC.
All brand names, product names and trademarks are the property of their respective owners. 
Savant Systems, LLC reserves the right to change product specifications without notice.

091812

Reviews: